The retrobulbar sinus is superior to the lateral tail vein for the injection of contrast media in small animal cardiac imaging.
نویسندگان
چکیده
Cardiac perfusion studies using computed tomography are a common tool in clinical practice. Recent technical advances and the availability of dedicated small animal scanners allow the transfer of these techniques to the preclinical sector in general and to mouse models of cardiac diseases in particular. This necessitates new requirements for contrast injection techniques as a rapid transport of contrast media from the intravenous access to the animal heart. Clinical contrast agents containing high iodine concentrations are used within small animal studies although they exhibit a high viscosity which might limit their transport within the vasculature. The authors provide a comparison of the transport of contrast media following an injection into the lateral tail vein and an injection into the retrobulbar sinus and discuss the anatomy involved. The temporal evolution of a contrast bolus and its in vivo distribution is visualized. It is demonstrated that injecting contrast agents into the lateral tail vein of mice results in a retrograde blood flow to the liver veins and therefore does not deliver a detectable contrast bolus to the heart, and thus it cannot be used for cardiac perfusion studies. By contrast, boli injected into the retrobulbar sinus are rapidly transported to the heart and provide ventricular contrast enabling perfusion studies similar to those in human patients. The results demonstrate that an injection into the retrobulbar sinus is superior to an injection into the lateral tail vein for the delivery of contrast boli to the animal heart, while all drawbacks of an injection into the lateral tail vein are overcome.
منابع مشابه
بهینه سازی نگاره های MRA مغز با استفاده از ماده کنتر است زا در میدان مغناطیسی 1.5 تسلا
Background and purpose: Selection of suitable parameters for brain MRA requires accurate measures, because the image quality depends on the location of arteries, veins and also the velocity differences of blood, taking into account the low blood flow in small veins and arteries, use of paramagnetic contrast media is recommended. Hence, in present study, we investigated the imaging optimizatio...
متن کاملAnatomic distribution of gadolinium contrast medium by high-resolution magnetic resonance imaging after peribulbar and retrobulbar injections.
OBJECTIVE To examine the anatomic distribution of gadolinium contrast medium by high-resolution surface-coil magnetic resonance imaging after peribulbar and retrobulbar injection. METHODS Comparative case series in which 4 healthy volunteers were randomized to peribulbar (n = 2) or retrobulbar (n = 2) injection of gadolinium and lidocaine hydrochloride, 2%, without epinephrine. Magnetic reson...
متن کاملThrombolytic Therapy for Cerebral Vein Thrombosis in Antiphospholipid Syndrome Secondary to Systemic Lupus Erythematosus
A 20-year-old woman was admitted to a Gynecology Hospital in her 6th month of pregnancy for high blood pressure and tonic-clonic seizure. Primary diagnosis was eclampsia, and for that reason she underwent cesarean section. She also had headache on frontal and parietal areas without nausea or vomiting. There was not a focal neurological sign. Rheumatology consultation was requested. Systemic lup...
متن کاملImaging of Clot by 99mTc-HMPAO Labeled Platelet in Animal Model Induced Thrombosis
99mTc-HMPAO labeled platelet (LP) imaging may integrate thrombosis imaging into routine clinical procedures. In the current study, we assessed the feasibility of the use of 99mTc-HMPAO LP for imaging of small clots in an animal model. Thrombosis was induced by application of FeCl3 solution in the distal part of the inferior vena cava (IVC) of a 6100 g anesthetiz...
متن کاملImaging of Clot by 99mTc-HMPAO Labeled Platelet in Animal Model Induced Thrombosis
99mTc-HMPAO labeled platelet (LP) imaging may integrate thrombosis imaging into routine clinical procedures. In the current study, we assessed the feasibility of the use of 99mTc-HMPAO LP for imaging of small clots in an animal model. Thrombosis was induced by application of FeCl3 solution in the distal part of the inferior vena cava (IVC) of a 6100 g anesthetiz...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Laboratory animals
دوره 48 2 شماره
صفحات -
تاریخ انتشار 2014