Magnetic resonance elastography using 3D gradient echo measurements of steady-state motion.

نویسندگان

  • J B Weaver
  • E E Van Houten
  • M I Miga
  • F E Kennedy
  • K D Paulsen
چکیده

Magnetic resonance elastography (MRE) is an important new method used to measure the elasticity or stiffness of tissues in vivo. While there are many possible applications of MRE, breast cancer detection and classification is currently the most common. Several groups have been developing methods based on MR and ultrasound (US). MR or US is used to estimate the displacements produced by either quasi-static compression or dynamic vibration of the tissue. An important advantage of MRE is the possibility of measuring displacements accurately in all three directions. The central problem in most versions of MRE is recovering elasticity information from the measured displacements. In previous work, we have presented simulation results in two and three dimensions that were promising. In this article, accurate reconstructions of elasticity images from 3D, steady-state experimental data are reported. These results are significant because they demonstrate that the process is truly three-dimensional even for relatively simple geometries and phantoms. Further, they show that the integration of displacement data acquisition and elastic property reconstruction has been successfully achieved in the experimental setting. This process involves acquiring volumetric MR phase images with prescribed phase offsets between the induced mechanical motion and the motion-encoding gradients, converting this information into a corresponding 3D displacement field and estimating the concomitant 3D elastic property distribution through model-based image reconstruction. Fully 3D displacement fields and resulting elasticity images are presented for single and multiple inclusion gel phantoms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Dual-Stage Reconstruction Algorithm for Magnetic Resonance Elastography

METHODS Spin echo encoded, steady-state harmonic motion data was collected from a cylindrical, gelatine phantom containing multiple inclusions in order to test a dual-stage Magnetic Resonance Elastography (MRE) reconstruction approach. This reconstruction method uses a viscoelastic shear modulus distribution calculated from derivatives of filtered displacement values as an initial guess for an ...

متن کامل

I-51: Pioneering New Approaches to Reproductive Imaging

Background: Gynecologic conditions including uterine fibroids, adenomyosis and endometriosis lead to significant impairment in women’s’ lives and significant expen- Abstracts of the 12th Royan International Congress on Reproductive Biomedicine International Journal of Fertility & Sterility (IJFS), Vol 5, Suppl 1, Summer 2011 24 ditures of health care dollars. However, many women have symptoms l...

متن کامل

3D steady-state diffusion-weighted imaging with trajectory using radially batched internal navigator echoes (TURBINE).

While most diffusion-weighted imaging (DWI) is acquired using single-shot diffusion-weighted spin-echo echo-planar imaging, steady-state DWI is an alternative method with the potential to achieve higher-resolution images with less distortion. Steady-state DWI is, however, best suited to a segmented three-dimensional acquisition and thus requires three-dimensional navigation to fully correct for...

متن کامل

Cardiac magnetic resonance elastography. Initial results.

OBJECTIVES To develop cardiac magnetic resonance elastography (MRE) for noninvasively measuring left ventricular (LV) pressure-volume (P-V) work. MATERIAL AND METHODS The anterior chest wall of 8 healthy volunteers was vibrated by 24.3-Hz acoustic waves for stimulating oscillating shear deformation in myocardium and adjacent blood. The induced motion was recorded by an electrocardiogram-gated...

متن کامل

Magnetic Resonance Imaging of Pulmonary Embolism: Diagnostic accuracy of contrast-enhanced 3D MRA, contrast- enhanced low flip angle 3D gradient echo and noncontrast steady-state free precession sequences

Introduction: Acute pulmonary thromboembolic disease is a significant cause of morbidity and mortality, with estimated yearly incidence of 650,000 cases in the USA. Pulmonary computed tomography angiography (CTA) is the current gold standard for PE diagnosis. However CTA has limitations regarding the use of iodinated contrast and relatively high ionizing radiation burdens, a consideration given...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 28 8  شماره 

صفحات  -

تاریخ انتشار 2001