Application of a single needle type for all image-guided biopsies: results of 100 consecutive core biopsies in various organs using a novel tri-axial, end-cut needle

نویسندگان

  • S Diederich
  • B Padge
  • U Vossas
  • R Hake
  • S Eidt
چکیده

PURPOSE To assess feasibility, results and complications in image-guided biopsies using a single needle design in various organs. MATERIALS AND METHODS 100 consecutive percutaneous biopsies were performed in 54 females and 46 males aged 24-87 years (mean age/standard deviation: 64.5 +/- 12 years) using a full-core end-cut tri-axial full-automatic biopsy needle (18 gauge BioPince, InterV-MDTech, Gainesville, Florida) under CT (n = 45) or ultrasound (n = 55) guidance. In 63 biopsies a coaxial technique was used. RESULTS Biopsies were obtained of liver (n = 32), lymph nodes (n = 17), thyroid (n = 11), lung (n = 9), adrenal (n = 9), pelvis (n = 6), chest wall/pleura (n = 6), mediastinum (n = 4), lytic bone lesions (n = 2), retroperitoneum (n = 1), muscle (n = 1), pancreas (n = 1), peritoneum (n = 1). Between 1 and 6 (mean/SD 2.83 +/- 0.92) needle passes were performed. In 77 cases a malignant (40 metastases, 37 primary tumours) and in 23 a benign lesion was diagnosed. Of the 23 benign lesions a specific diagnosis was possible in 22. In one case necrosis and haemorrhage was diagnosed. In this patient surgery and autopsy both revealed a mediastinal haematoma of unknown origin. Eight minor complications (mild pain/local haematoma requiring no therapy) and three major complications (three pneumothoraces in nine lung biopsies requiring two aspirations and one drainage) were observed. There was no mortality. CONCLUSION Percutaneous image-guided biopsy using the described full-core end-cut needle resulted in a specific diagnosis in 99/100 consecutive biopsies in various organs with a low complication rate. We use this needle type for all CT- or US-guided biopsies in all organs except for solid bone.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی نمونه‌های آسیب‌شناسی حاصل از بیوپسی سوزنی با هدایت سی‌تی‌اسکن در ضایعات قفسه سینه بیماران مراجعه‌کننده به بخش پاتولوژی بیمارستان شهید صدوقی یزد

Introduction: Despite the popularity of needle biopsy for obtaining tissue samples in several solid organs, its use in thoracic lesions has been very restricted in some hospitals. This study intended to investigate the CT-Guided transthoracic core needle biopsy specimens in Yazd Shahid Sadoughi hospital during 2001- 2010. Methods: This is a retrospective cross- sectional study conducted on pat...

متن کامل

PERCUTANEOUS TRANSTHORACIC BIOPSY USING TRU-CUT NEEDLE

Biopsies of thoracic lesions guidance. 22 of the 1 12 lesions were mediastinal and 83 were pleuroparenchymal. A large-bore 14-gauge Tru-cut needle was used in all patients. Adequate specimens for histologic examination were obtained in 98%. The overall accuracy was 91 % with 9% false negative and no false positive diagnoses. Despite the large size of the needle, the total number of complic...

متن کامل

Percutaneous needle biopsy of the mediastinum: review of 94 procedures.

BACKGROUND A number of reports of radiologically guided percutaneous biopsy of mediastinal masses have been described but techniques have varied, particularly the type of needle used. In this study mediastinal biopsies with fine aspiration needles and cutting needles have been compared, sometimes in the same patient. The results are reviewed with particular emphasis on the choice of biopsy need...

متن کامل

Reducing the cost of diagnosis of breast carcinoma: impact of ultrasound and imaging-guided biopsies on a clinical breast practice.

BACKGROUND The objective of this study was to determine whether the use of ultrasound and percutaneous breast biopsies in patients with screen-detected nonpalpable abnormalities can reduce benign open surgical biopsies of the breast without increasing cost or sacrificing detection of potentially curable breast carcinomas. METHOD Using a computerized mammography database and consecutive logs o...

متن کامل

Chest wall sarcomas are accurately diagnosed by image-guided core needle biopsy.

OBJECTIVE Sarcomas are rare mesenchymal malignancies. Accurate preoperative diagnosis is a prerequisite in considering investigational or institutional management algorithms that include neoadjuvant treatment. We reviewed our experience using core needle biopsy for chest wall sarcomas. METHODS A retrospective review of our sarcoma databases revealed that 40 core needle biopsies and 35 tumor r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Cancer Imaging

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2006