Cesium-129 myocardial scintigraphy to quantify myocardial infarction in dogs.

نویسندگان

  • D W Romhilt
  • A B Ashare
  • R J Adolph
  • N I Levenson
  • W G Wee
  • V J Sodd
  • L S August
چکیده

The sizes of surgically induced acute myocardial infarctions were quantified in a study of 28 dogs. Four projections (right and left anterior oblique, anterior, and left lateral) were obtained with 129Cs myocardial scintigraphy. Control images, taken before surgery, were compared with images taken 24-72 hr after coronary artery ligation. From postmortem examination the size of the infarct was determined and expressed as a percentage of the total left ventricle. On a standard diagram four independent observers marked the infarcted areas in each projection, expressed the severity of involvement in each area, and determined overall infarction size as a percentage of the total left ventricle. A nonlinear least-squares method was also employed to derive the size of the infarct, using the results from each observer's diagram. There were positive correlations between each observer's percentage estimate and the autopsy results. The overall accuracy of the least-squares method was similar to that of the individual observers. In this study, Observer 3 proved that acute myocardial infarcts can be quantified accurately from multiple scintigraphic projections of the myocardium, but the other three observers had difficulty in estimating infarct size. This difficulty probably resulted from the lack of well-validated criteria to aid the observer in determining the area of infarction, the severity of involvement within that area, or the total size of a myocardial infarct. Improvement in these estimates will require the development of definitive criteria, the use of optical scanners or computer processing, and combinations of radionuclides.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cesium-129 myocardial scintigraphy to detect myocardial infarction.

Cesium-129 is concentrated in the myocardium after intravenous administration permitting myocardial imaging. The dosage used was 2-2.5 mCi in dogs and 3-4 mCi in patients. Four or more views with 200,000 counts per view were obtained 30 to 90 minutes after administration. Control images were obtained in 30 dogs. In two dogs anatomic landmarks were obtained using technetium-99m markers. In 24 do...

متن کامل

Prediction of long-term cardiac events by 123I-MIBG imaging after acute myocardial infarction and reperfusion therapy

Objective(s): In heart failure, the heart-to-mediastinum (H/M) ratio of the delayed image and washout rate (WR) are well-known as a powerful cardiac event predictors. H/M ratio quantifies the accumulation rate of MIBG in the myocardium and WR quantifies reduction of meta-iodobenzylguanidine (MIBG) accumulation in the heart from the early planar image to the delayed pla...

متن کامل

Myocardial damage of the entire ventricular region in a patient with acute myocardial infarction

Technetium-99m-pyrophosphate (99mTc-PYP) has been used, in combination with thallium-201, to estimate the site and extent of myocardial infarcts. We report a case of acute myocardial infarction with severe coronary disease in which the distribution of 99mTc-PYP was extensive. A 78-year-old man presented with dyspnea, and a diagnosis of non-ST-segment elevation acute myocar...

متن کامل

Effects of depression on myocardial perfusion scintigraphy [Persian]

  Introduction: The relationship between depression and coronary artery disease is well established; however assessment of this relationship using functional and semi-quantitative imaging (myocardial perfusion scintigraphy) was lacking. The aim of this study was to assess the relationship between the severity of depression and the severity of myocardial perfusion abno...

متن کامل

Hemodynamic Findings in Patients with Anomalous Origin of the Coronary Arteries

a new radiopharmaceutical for imaging the heart. J NucI Med 12: 516, 1971 6. Gorten RJ: Clinical testing of 3K scans of the heart. J Nucl Med 13: 432, 1972 7. Smith RO, Bennett KR, Lehan PH, Hellems HK: Myocardial 42K scanning compared with coronary arteriography. (abstr) J Nucl Med 11: 642, 1970 8. Love WD, Ishihasa Y, Lyons LD, Smith RO: Differences in the relationships between coronary blood...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 17 4  شماره 

صفحات  -

تاریخ انتشار 1976