A validated, sensitive HPLC-MS/MS method for quantification of cis-para-methyl-4-methylaminorex (cis-4,4'-DMAR) in rat and human plasma: application to pharmacokinetic studies in rats.
نویسندگان
چکیده
4,4'-DMAR is an analogue of the known psychostimulants 4-methylaminorex and aminorex. In the light of reports of deaths associated with its abuse, and the easy access from Internet vendors, the EU Council recently decided on control measures across member states. Here we describe a validated method for measuring plasma levels of cis-4,4'-DMAR, crucial for preclinical studies and analysis in human plasma. Chromatographic separation was done by gradient elution on a Kinetex C18 column with 0.1% formic acid in water and 0.1% formic acid in acetonitrile at 0.2 mL/min. Detection was by positive electrospray ionization (ESI+) in multiple reaction monitoring mode monitoring the quantifier transitions m/z 191.4 → m/z 148.3 for cis-4,4'-DMAR and m/z 259.3 → m/z 194.2 for carbamazepine (internal standard). Protein precipitation with 1% of formic acid in acetonitrile was used in cis-4,4'-DMAR extraction from plasma; recovery was high (>93%) with a negligible matrix effect. This method provides an accurate, precise, and sensitive method for cis-4,4'-DMAR quantification in human and rat plasma, following European Medicine Agency guidelines for bioanalytical method validation. Pharmacokinetic studies were conducted in rats. After an intravenous dose of 1 mg/kg, plasma levels declined rapidly (≥80% in 4 h), followed by a slow elimination phase (t1/2 of 5.14 ± 0.65 h). Absorption was rapid after intraperitoneal injection (tmax = 15 min) with a rapid decline thereafter; Cmax and AUC0-240min showed dose-proportionality over the dose range 1-10 mg/kg. This method was successfully applied to investigate pharmacokinetic properties in rats and could be used to quantify cis-4,4'-DMAR levels in human plasma. Copyright © 2016 John Wiley & Sons, Ltd.
منابع مشابه
A Simple and Sensitive HPLC Method for Fluorescence Quantitation of Doxorubicin in Micro-volume Plasma: Applications to Pharmacokinetic Studies in Rats
A validated HPLC method was developed to determine doxorubicin concentration in a small volume of rat plasma (60 µl) with convenient fluorescence detection. Sample preparation includes a simple one-step liquid-liquid extraction using minimum amount of organic solvent, with extraction recoveries more than 95%. The analysis was accomplished using PerfectSil C18 column maintained at 35 °C and a mo...
متن کاملA Simple and Sensitive HPLC Method for Fluorescence Quantitation of Doxorubicin in Micro-volume Plasma: Applications to Pharmacokinetic Studies in Rats
A validated HPLC method was developed to determine doxorubicin concentration in a small volume of rat plasma (60 µl) with convenient fluorescence detection. Sample preparation includes a simple one-step liquid-liquid extraction using minimum amount of organic solvent, with extraction recoveries more than 95%. The analysis was accomplished using PerfectSil C18 column maintained at 35 °C and a mo...
متن کاملA quick and Sensitive Liquid Chromatography–tandem Mass Spectrometry (LC-MS) Method for the Determination of Enalapril and Enalaprilat in Human Plasma: Application to a Bioequivalence Study
A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC-MS) method for the estimation of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode was operated under the multiple-reaction monitoring mode. Sample pretreatment involved in a one-step protein precipitat...
متن کاملRapid High Performance Liquid Chromatographic Method for Determination of Clarithromycin in Human Plasma Using Amperometric Detection: Application in Pharmacokinetic and Bioequivalence Studies
A rapid, sensitive and reproducible HPLC method using amperometric detector was developed and validated for the analysis of clarithromycin in human plasma. The separation was achieved on a monolithic silica column (MZ- C8 125×4.0 mm) using acetonitrile- methanol-potassium dihydrogen phosphate buffer (40:6:54,v/v), with pH of 7.5, as the mobile phase at a flow rate of 1.5 mL/min. The assay enabl...
متن کاملRapid High Performance Liquid Chromatographic Method for Determination of Clarithromycin in Human Plasma Using Amperometric Detection: Application in Pharmacokinetic and Bioequivalence Studies
A rapid, sensitive and reproducible HPLC method using amperometric detector was developed and validated for the analysis of clarithromycin in human plasma. The separation was achieved on a monolithic silica column (MZ- C8 125×4.0 mm) using acetonitrile- methanol-potassium dihydrogen phosphate buffer (40:6:54,v/v), with pH of 7.5, as the mobile phase at a flow rate of 1.5 mL/min. The assay enabl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Drug testing and analysis
دوره 9 6 شماره
صفحات -
تاریخ انتشار 2017