Proposal of a magnetic resonance technique for the evaluation of the calcaneofibular ligament minimizing false positive results

نویسندگان

  • Ibevan A Nogueira
  • Annie F Frère
  • Alessandro P Silva
  • Terigi A Scardovelli
  • Silvia RMS Boschi
  • Heverton C Oliveira
چکیده

BACKGROUND Magnetic resonance (MR) techniques used to detect lesions of the ligament complex for articulation of the ankle lack the desired accuracy for the study of the calcaneofibular ligament (CFL). The lack of sensitivity of the conventional techniques is due to variations in the dimensions of the CFL. The best results are obtained when the image plane is oriented parallel to the ligament. This study aims to develop a model that addresses the width, length and angle parameters of the CFL and the orientation of the MR image plane, and thus determine a technique in the oblique transversal plane with the foot in anatomical flexion, that is adequate for the majority of patients. METHOD To determine this orientation and adapt it to the majority of people, images of the articulation of the ankle in the 3D isotropic, volumetric, sagittal plane of 100 volunteers were taken using the MR technique. None of the volunteers had a clinical history of ligament lesions, serious pathologies, or surgeries. A measurement of the length, width, and angle of the CFL relative to the sole of the foot was performed using the MR tools. A virtual model was developed that simulated the visualization of the CFL in the oblique transversal image plane from 35° to 45° using the CFL dimensions of 100 volunteers. The comparison of the simulations with the reconstructed images validated the model and permitted the calculation of the agreement and sensitivity of each technique in the detection of the complete CFL. RESULTS Using the simulator, it was possible to obtain the limit angle for complete CFL visualization as a function of its dimensions for any angle of the oblique transversal image plane of the MR. CONCLUSION The results suggest that a single image acquisition technique in the oblique transversal plane at 38° with the foot in anatomical flexion would serve the majority of patients.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Magnetic resonance imaging evaluation of lateral ankle ligaments and peroneal tendons in a group of asymptomatic patients

Background: The role of magnetic resonance (MR) imaging in patients with lateral ankle instability remains unclear. This study reports the MR findings in patients with asymptomatic ankles.Materials and Methods: A total of 14 ankles in 11 asymptomatic patients were evaluated using 3.0 Tesla MR scanners. Imaging planes included axial PD and T2 weighted sequences, coronal fatsaturated PD fast spin...

متن کامل

Accuracy of MRI in Comparison with Arthroscopic Findings in the Diagnosis of Anterior Cruciate Ligament and Meniscus Tears

Background: Magnetic resonance imaging (MRI) is of great aid in the diagnosis of knee lesions. Nevertheless, arthroscopy has remained the reference standard for the diagnosis of internal derangements of the knee, against which alternative diagnostic modalities should be compared. This study was designed to assess the value of MRI and clinical examination in the diagnosis of Anterior Cruciate Li...

متن کامل

Study of Coincidence of Hoffa’s Fat Pad Associated Injuries in Knee Traumas in Magnetic Resonance Imaging

Background and Objective: Hoffa’s fat pad injuries are often caused by acute direct and indirect trauma and chronic recurrent micro-trauma, and its disorders are associated with other traumas and injuries that have been less paid attention to in radiological studies. Therefore, this study was performed to evaluate the injuries associated with Hoffa’s fat pad injury in knee trauma using the diag...

متن کامل

Accuracy of magnetic resonance imaging in diagnosing lateral ankle ligament injuries: A comparative study with surgical findings and timings of scans

Objective This study aimed to evaluate the accuracy of magnetic resonance imaging (MRI) in diagnosing lateral ankle ligament injuries and the effect of differences in time duration from injury to MRI. Methods Data were collected prospectively from 82 patients who underwent MRI and lateral ligament reconstruction, and were divided into either acute (≤3 months) or chronic (>3 months) group base...

متن کامل

Effect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies

Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of the estimated PK parameters is essential when they are used as a measure for therapy evaluation or treatment planning. In this study, the accuracy of PK parameters in brain DCE...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2014