Parallel imaging with phase scrambling.

نویسندگان

  • Maxim Zaitsev
  • Gerrit Schultz
  • Juergen Hennig
  • Rolf Gruetter
  • Daniel Gallichan
چکیده

PURPOSE Most existing methods for accelerated parallel imaging in MRI require additional data, which are used to derive information about the sensitivity profile of each radiofrequency (RF) channel. In this work, a method is presented to avoid the acquisition of separate coil calibration data for accelerated Cartesian trajectories. METHODS Quadratic phase is imparted to the image to spread the signals in k-space (aka phase scrambling). By rewriting the Fourier transform as a convolution operation, a window can be introduced to the convolved chirp function, allowing a low-resolution image to be reconstructed from phase-scrambled data without prominent aliasing. This image (for each RF channel) can be used to derive coil sensitivities to drive existing parallel imaging techniques. As a proof of concept, the quadratic phase was applied by introducing an offset to the x(2) - y(2) shim and the data were reconstructed using adapted versions of the image space-based sensitivity encoding and GeneRalized Autocalibrating Partially Parallel Acquisitions algorithms. RESULTS The method is demonstrated in a phantom (1 × 2, 1 × 3, and 2 × 2 acceleration) and in vivo (2 × 2 acceleration) using a 3D gradient echo acquisition. CONCLUSION Phase scrambling can be used to perform parallel imaging acceleration without acquisition of separate coil calibration data, demonstrated here for a 3D-Cartesian trajectory. Further research is required to prove the applicability to other 2D and 3D sampling schemes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Single Coil PILS Imaging Using Phase-Scrambling Fourier Transform Technique

Introduction Parallel image reconstruction using local sensitivities (PILS)[1] accelerate MR scan time by using multiple receiver coil in parallel scan time. We propose a novel imaging technique which is based on the PILS, but uses only a single set of signals. The signal obtained in the phase-scrambling Fourier Transform imaging (PSFT)[2] can be transformed into the signal described by the Fre...

متن کامل

Reference-Free Parallel Imaging with Phase Scrambling (PIPS)

INTRODUCTION: A failure to fulfil sampling requirements in MRI results in aliasing. Receiver coil arrays allow accelerating Fourier encoding by relaxing k-space sampling rules. Parallel imaging either interpolates missing k-space lines [1] or undoes aliasing in image domain [2]. Coil sensitivity data are acquired either prior to the actual scan or as a fully sampled part of k-space (auto-calibr...

متن کامل

Anti-alias Imaging by Fresnel Scalable Image Reconstruction

INTRODUCTION A novel image reconstruction technique, which avoids aliasing artifacts by scalable image reconstruction in Magnetic Resonance Imaging, is proposed. The signal obtained in the phase-scrambling Fourier imaging technique can be transformed to the signal described in the Fresnel transform equation of the objects. Therefore, image reconstruction can be performed not only by inverse Fou...

متن کامل

Effect of Phase-Encoding Reduction on Geometric Distortion and BOLD Signal Changes in fMRI

Introduction Echo-planar imaging (EPI) is a group of fast data acquisition methods commonly used in fMRI studies. It acquires multiple image lines in k-space after a single excitation, which leads to a very short scan time. A well-known problem with EPI is that it is more sensitive to distortions due to the used encoding scheme. Source of distortion is inhomogeneity in the static B0 field that ...

متن کامل

A Theoretical Analysis of One-time Key Based Phase Scrambling for Phase-only Correlation between Visually Protected Images

We present a theoretical analysis of one-time key based phase scrambling for image matching using phase-only correlation (POC). Phase scrambling is used for visual information protection of templates. The effect of scrambling on POC values is analyzed. As a result, the peak value, which is used as a measure of signal congruence, of the POC between nonscrambled signals can be estimated by observ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 73 4  شماره 

صفحات  -

تاریخ انتشار 2015