Electromyography and bite force studies of muscular function and dysfunction in masticatory muscles.

نویسنده

  • C Hagberg
چکیده

Electromyographic (EMG) activity versus bite force was studied during a gradually increased isometric contraction up to maximal effort for patients with painful masseter muscles and referents. The masseter muscle, the anterior temporal muscle and the descending part of the trapezius muscle were chosen for the recordings. Bite force was registered with a bite force sensor placed between the first molars. The effects of double blind intramuscular injections of lidocaine and saline in the patients' masseter muscle were evaluated by EMG versus bite force and by assessment of discomfort. EMG activity during unilateral chewing was compared in terms of relative masticatory force between referents and patients by amplitude probability distribution analysis. Regression analyses showed intra-individually steeper slopes for high force levels than for low force levels for the masseter muscle. This was not observed for the anterior temporal muscle. These differences in slopes of the EMG versus force regressions for the masseter muscle and the anterior temporal muscle could be due to differences in recruitment pattern. The same intra-individual relationship between low and high force levels was found for referents and patients. An increased activity, especially among the patients, was found for the descending part of the trapezius muscle during stronger activity of the mandibular elevators. The EMG versus force relationship for low force levels of the masseter muscle was less steep after an intramuscular injection of lidocaine but not after saline. Both solutions for injection had a positive effect on the patients' assessments of discomfort one week after the injection. Three days after injection the patients who received lidocaine experienced a reduction in muscular discomfort. This reduction was not found among patients receiving saline. The amplitude probability distribution analysis revealed that the patients used greater relative masticatory forces than the referents during the chewing of an almond for all probability levels analysed below the peak load of the masseter muscles. Rough estimates of the peak masticatory forces in Newton (N) were for chewing an almond 364 N (referents); 373 N (patients) and for gum-chewing 239 N (referents); 238 N (patients) as regards the masseter muscle. The values were similar for the anterior temporal muscle.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dynamic Modeling of the Electromyographic and Masticatory Force Relation Through Adaptive Neuro-Fuzzy Inference System Principal Dynamic Mode Analysis

Introduction: Researchers have employed surface electromyography (EMG) to study the human masticatory system and the relationship between the activity of masticatory muscles and the mechanical features of mastication. This relationship has several applications in food texture analysis, control of prosthetic limbs, rehabilitation, and teleoperated robots. Materials and Methods: In this paper, w...

متن کامل

Case report involving temporomandibular dysfunction, eagle’s syndrome and torus mandibularis —Multidisciplinary approaches

The prevalence of torus mandibularis, Eagle’s syndrome and parafunctional activity was reported to be higher in patients with temporomandibular joint dysfunction and might be useful as an indicator of increased risk of temporomandibular disorders. This study case report was to evaluate a 62-year-old female patient, with limited mandibular and cervical movements, articular and muscular pain, ear...

متن کامل

Electromyographic and cephalometric correlation with the predominant masticatory movement.

OBJECTIVE This study aimed to evaluate the chewing muscular dynamics and correlate the side of the masticatory movement that is more vertical and/or more horizontal established by the photomeasurement Masticatory Functional Angle (MFA) to the muscular activity behavior, showed in the surface electromyography and in the radiographic images. MATERIAL AND METHOD Seventeen people were selected of...

متن کامل

Functional Evaluation of the Behavior of Masticatory Muscles in Zygomaticomaxillary Complex Fracture: A Prospective Study.

AIMS The purpose of this study is to functionally evaluate the behavior of the masticatory muscles (masseter and temporalis) following zygomaticomaxillary complex (ZMC) fractures by assessing bite force, electromyography (EMG), and mandibular movements. MATERIALS AND METHODS Group I consisted of 20 patients with unilateral ZMC fractures who were treated surgically with one-, two-, or three-po...

متن کامل

Longitudinal effects of rapid maxillary expansion on masticatory muscles activity

BACKGROUND To investigate the modifications induced by rapid maxillary expansion (RME) on the electromyographic (EMG) activities of the anterior temporal and superficial masseter muscles, in patients without pre-treatment EMG alterations. MATERIAL AND METHODS Twenty-one patients with unilateral posterior cross-bite selected from the orthodontic department of the University of L'Aquila (Italy)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Swedish dental journal. Supplement

دوره 37  شماره 

صفحات  -

تاریخ انتشار 1986