Highly sensitive chemiluminescence technology for protein detection using aptamer-based rolling circle amplification platform

نویسندگان

  • Zhi-Juan Cao
  • Qian-Wen Peng
  • Xue Qiu
  • Cai-Yun Liu
  • Jian-Zhong Lu
چکیده

A robust, selective and highly sensitive chemiluminescent (CL) platform for protein assay was presented in this paper. This novel CL approach utilized rolling circle amplification (RCA) as a signal enhancement technique and the 96-well plate as the immobilization and separation carrier. Typically, the antibody immobilized on the surface of 96-well plate was sandwiched with the protein target and the aptamer-primer sequence. This aptamer-primer sequence was then employed as the primer of RCA. Based on this design, a number of the biotinylated probes and streptavidin-horseradish peroxidase (SA-HRP) were captured on the plate, and the CL signal was amplified. In summary, our results demonstrated a robust biosensor with a detection limit of 10 fM that is easy to be established and utilized, and devoid of light source. Therefore, this new technique will broaden the perspective for future development of DNA-based biosensors for the detection of other protein biomarkers related to clinical diseases, by taking advantages of high sensitivity and selectivity.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A versatile platform for highly sensitive detection of protein: DNA enriching magnetic nanoparticles based rolling circle amplification immunoassay.

A novel rolling circle amplification (RCA) immunoassay based on DNA enriching magnetic nanoparticles and assembled fluorescent DNA nanotags, magnetic nanoparticles-RCA immunoassay, is developed as a versatile fluorescence assay platform for highly sensitive proteins detection.

متن کامل

Sensitive detection of polynucleotide kinase using rolling circle amplification-induced chemiluminescence.

We develop a new method for the sensitive detection of polynucleotide kinase (PNK) using rolling circle amplification-induced chemiluminescence. This method exhibits high sensitivity with a detection limit of 2.20 × 10(-4) U mL(-1), which is superior to most reported approaches. Moreover, this method can be used to screen both the inhibitors and the activators of PNK, and can be further applied...

متن کامل

A facile scanometric strategy for ultrasensitive detection of protein using aptamer-initiated rolling circle amplification.

A pragmatic and simple strategy was developed for ultrasensitive detection of protein with good specificity and low matrix effect, which combined aptamer-initiated rolling circle amplification with a Au nanoparticle probe and convenient scanometric readout.

متن کامل

Rolling Circle Amplification (RCA): an approach for quick detection and identification of fungal species

Conventional methods for fungal identification in the clinical laboratory rely on morphological andphysiological tests. These tests often need several days or weeks to complete and are frequentlyunspecific. Molecular identification mostly implies sequencing, which is relatively expensive andtime-consuming, as well as impractical for large numbers of isolates. The Rolling CircleAmplification app...

متن کامل

Ultrasensitive detection of thrombin using surface plasmon resonance and quartz crystal microbalance sensors by aptamer-based rolling circle amplification and nanoparticle signal enhancement.

The surface plasmon resonance (SPR) and quartz crystal microbalance (QCM) aptasensors combined with rolling circle amplification and bio-bar-coded AuNP enhancement have been applied to detect the human α-thrombin for the first time. The assay platform exhibited excellent selectivity and sensitivity with detection limit as low as 0.78 aM.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2011