Calibration and Validation of a Wrist- and Hip-Worn Actigraph Accelerometer in 4-Year-Old Children

نویسندگان

  • Elin Johansson
  • Lisa-Marie Larisch
  • Claude Marcus
  • Maria Hagströmer
چکیده

INTRODUCTION To determine time spent at different physical activity intensities, accelerometers need calibration. The aim of this study was to develop and cross-validate intensity thresholds for the Actigraph GT3X+ accelerometer for wrist and hip placement in four-year-old children. METHODS In total 30 children (49 months, SD 3.7) were recruited from five preschools in Stockholm. Equipped with an accelerometer on the wrist and another on the hip, children performed three indoor activities and one free-play session while being video recorded. Subsequently, physical activity intensity levels were coded every 5th second according to the Children's Activity Rating Scale. Receiver Operating Characteristic (ROC) curves was used to develop wrist and hip intensity thresholds, the upper threshold for sedentary, and lower threshold for moderate-to-vigorous physical activity (MVPA), for the vertical axis (VA) and for the vector magnitude (VM). A leave-one-out method was used to cross-validate the thresholds. RESULTS Intensity thresholds for wrist placement were ≤ 178 (VA) and ≤ 328 (VM) for sedentary and ≥ 871 (VA) and ≥ 1393 (VM) counts/5 seconds for MVPA. The corresponding thresholds for hip placement were ≤ 43 (VA) and ≤ 105 (VM) for sedentary and ≥ 290 (VA) and ≥ 512 (VM) for MVPA. The quadratic weighted Kappa was 0.92 (95% CI 0.91-0.93) (VA) and 0.95 (95% CI 0.94-0.96) (VM) for the wrist-worn accelerometer and 0.76 (98% CI 0.74-0.77) and 0.86 (95% CI 0.85-0.87) for the hip-worn. CONCLUSION Using wrist placement and the VM when measuring physical activity with accelerometry in 4-year-old children is recommended.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calibration of the GENEA accelerometer for assessment of physical activity intensity in children.

OBJECTIVES The purpose of the study was to establish activity intensity cut-points for the GENEA accelerometer via calibration with oxygen consumption (V˙⁡O(2)). DESIGN The study was a lab-based validation and calibration study. METHODS Forty-four children, aged 8-14 years, completed eight activities (ranging from lying supine to a medium paced run) whilst wearing GENEA accelerometers at th...

متن کامل

Validity and Comparability of a Wrist-Worn Accelerometer in Children.

BACKGROUND: Wrist-worn accelerometers may provide an alternative to hip-worn monitors for assessing physical activity as they are easier to wear and may thus facilitate long-term recordings. The present study aimed at a) assessing the validity of the Actiwatch (wrist-worn) for estimating energy expenditure b) determine cut-off values for light, moderate and vigorous activities, c) studying the ...

متن کامل

Accelerometer counts and raw acceleration output in relation to mechanical loading.

The purpose of this study was to assess the relationship of accelerometer output, in counts (ActiGraph GT1M) and as raw accelerations (ActiGraph GT3X+ and GENEA), with ground reaction force (GRF) in adults. Ten participants (age: 29.4 ± 8.2 yr, mass: 74.3 ± 9.8 kg, height: 1.76 ± 0.09 m) performed eight trials each of: slow walking, brisk walking, slow running, faster running and box drops. GRF...

متن کامل

Methods to estimate aspects of physical activity and sedentary behavior from high-frequency wrist accelerometer measurements.

This investigation developed models to estimate aspects of physical activity and sedentary behavior from three-axis high-frequency wrist-worn accelerometer data. The models were developed and tested on 20 participants (n = 10 males, n = 10 females, mean age = 24.1, mean body mass index = 23.9), who wore an ActiGraph GT3X+ accelerometer on their dominant wrist and an ActiGraph GT3X on the hip wh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016