Comparison of aneroid and oscillometric blood pressure measurements in children.
نویسندگان
چکیده
Limited data exist on the comparison of blood pressure (BP) measurements using aneroid and oscillometric devices. The purpose of the study was to investigate the difference in BP obtained using oscillometric and aneroid BP monitors in 9- to 10-year-old children. A total of 979 children were divided into group O, which underwent two oscillometric BP readings followed by two aneroid readings, and group A, which had BP measured in the reverse order. No significant difference was found between the mean (±standard deviation) of the two systolic BP readings obtained using the oscillometric and aneroid devices (111.5±8.6 vs 111.3±8.1 mm Hg; P=.39), whereas the mean diastolic BP was lower with the oscillometric monitor (61.5±8.0 vs 64.5±6.8 mm Hg; P<.001). A significant downward trend in BP was observed with each consecutive measurement, and agreement between the two monitors was limited. Multiple BP measurements are, therefore, recommended before the diagnosis of elevated BP or hypertension is made with either method.
منابع مشابه
Blood pressure measurement in children
In pediatric age diagnosis of hypertension is defined using a statistical criterion, the limit being the 95th percentile of the distribution of the blood pressure values, according to gender, age and height [1]. Prehypertension is defined as blood pressure (BP) values consistently above or equal to the 90th percentile, but lower than the 95th [Table 1]. The “gold standard” method to measure BP ...
متن کاملArterial blood pressure monitoring in overweight critically ill patients: invasive or noninvasive?
INTRODUCTION Blood pressure measurements frequently guide management in critical care. Direct readings, commonly from a major artery, are considered to be the gold standard. Because arterial cannulation is associated with risks, alternative noninvasive blood pressure (NIBP) measurements are routinely used. However, the accuracy of NIBP determinations in overweight patients in the outpatient set...
متن کاملComparison of mercury and aneroid blood pressure measurements in youth.
OBJECTIVE Because of concerns about the safety and environmental impact of mercury, aneroid sphygmomanometers have replaced mercury-filled devices for blood pressure (BP) measurements. Despite this change, few studies have compared BP measurements between the 2 devices. METHODS The SEARCH for Diabetes in Youth Study conducted a comparison of aneroid and mercury devices among 193 youth with di...
متن کاملStrategies to Reduce Pitfalls in Measuring Blood Pressure
Errors in blood pressure (BP) measurement are common in the clinical practice. Inaccurate measurements of BP may lead to misdiagnosis and inappropriate treatment of hypertension. The preferred method of BP measurement in the clinical setting is auscultation, using the first and the fifth Korotkoff sounds. However, the use of mercury sphygmomanometer is declining. Automated oscillometric devices...
متن کاملAlternatives to the mercury sphygmomanometer.
The mercury sphygmomanometer was introduced over 100 years ago. Mercury, however, is a potent human neurotoxin. An international effort has developed to eliminate health-care sources of mercury--the thermometer and sphygmomanometer--and replace them with less toxic alternatives. There is concern regarding the accuracy of these alternative devices. We conducted a literature review of articles pu...