Comparing proton treatment plans of pediatric brain tumors in two pencil beam scanning nozzles with different spot sizes

نویسندگان

  • John C. Kralik
  • Liwen Xi
  • Timothy D. Solberg
  • Charles B. Simone
  • Liyong Lin
چکیده

Target coverage and organ-at-risk sparing were compared for 22 pediatric patients with primary brain tumors treated using two distinct nozzles in pencil beam scanning (PBS) proton therapy. Consecutive patients treated at our institution using a PBS-dedicated nozzle (DN) were replanned using a universal nozzle (UN) beam model and the original DN plan objectives. Various cranial sites were treated among the patients to prescription doses ranging from 45 to 54 Gy. Organs at risk (OARs) evaluated were patient-dependent; 15 unique OARs were analyzed, all of which were assessed in at least 10 patients. Clinical target volume (CTV) coverage and organ sparing were compared for the two nozzles using dose-volume histogram data. Statistical analysis using a confidence-interval approach demonstrates that CTV coverage is equivalent for UN and DN plans within ± 5% equivalence bounds. In contrast, average mean and maximum doses are significantly higher for nearly all 15 OARs in the UN plans. The average median increase over all OARs and patients is approximately 1.7 Gy, with an increase in the 25%-75% of 1.0-2.3 Gy; the median increase to the pituitary gland, temporal lobes, eyes and cochleas are 1.8, 1.7, 0.7, and 2.7 Gy, respectively. The CTV dose distributions fall off slower for UN than for the DN plans; hence, normal tissue structures in close proximity to CTVs receive higher doses in UN plans than in DN plans. The higher OAR doses in the UN plans are likely due to the larger spot profile in plans created with UN beams. In light of the high rates of toxicities in pediatric patients receiving cranial irradiation and in light of selected brain tumor types having high cure rates, this study suggests the smaller DN beam profile is preferable for the advantage of reducing dose to OARs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric consequences of pencil beam width variations in scanned beam particle therapy.

Scanned ion beam delivery enables the highest degree of target dose conformation attainable in external beam radiotherapy. Nominal pencil beam widths (spot sizes) are recorded during treatment planning system commissioning. Due to changes in the beam-line optics, the actual spot sizes may differ from these commissioning values, leading to differences between planned and delivered dose. The purp...

متن کامل

A comparison of the dose distributions from three proton treatment planning systems in the planning of meningioma patients with single‐field uniform dose pencil beam scanning

With the number of new proton centers increasing rapidly, there is a need for an assessment of the available proton treatment planning systems (TPSs). This study compares the dose distributions of complex meningioma plans produced by three proton TPSs: Eclipse, Pinnacle3, and XiO. All three systems were commissioned with the same beam data and, as best as possible, matched configuration setting...

متن کامل

Comparison of multi‐institutional Varian ProBeam pencil beam scanning proton beam commissioning data

PURPOSE Commissioning beam data for proton spot scanning beams are compared for the first two Varian ProBeam sites in the United States, at the Maryland Proton Treatment Center (MPTC) and Scripps Proton Therapy Center (SPTC). In addition, the extent to which beams can be matched between gantry rooms at MPTC is investigated. METHOD Beam data for the two sites were acquired with independent dos...

متن کامل

Effects of Defining Realistic Compositions of the Ocular Melanoma on Proton Therapy

Background: Recent studies in eye plaque brachytherapy have shown a considerable difference between the dosimetric results using water phantom and a model of human eye containing realistic materials. In spite of this fact, there is a lack of simulation studies based on such a model in proton therapy literatures. In the presented work, the effect of utilizing an eye model with ocular media on pr...

متن کامل

A Monte Carlo pencil beam scanning model for proton treatment plan simulation using GATE/GEANT4.

This work proposes a generic method for modeling scanned ion beam delivery systems, without simulation of the treatment nozzle and based exclusively on beam data library (BDL) measurements required for treatment planning systems (TPS). To this aim, new tools dedicated to treatment plan simulation were implemented in the Gate Monte Carlo platform. The method was applied to a dedicated nozzle fro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2015