Determination of trace elements in cells is critical to metallomics research and still faces tremendous difficulties even with the help of highly sensitive inductively coupled plasma mass spectrometry (ICP-MS). Microfluidic chips offer a functional tool-set for cell analysis with features of miniaturization, integration and automation. In this work, we proposed a chip-based array magnetic solid phase microextraction (MSPME) system and on-line combined it with ICP-MS via microflow concentric nebulization for the determination of trace Cu, Zn, Cd, Hg, Pb and Bi in cells. Under the optimized conditions, the limits of detection of the developed on-line chip-based array MSPME-ICP-MS system are 49, 43, 4.2, 6.1, 13 and 18 ng L(-1) for Cu, Zn, Cd, Hg, Pb and Bi, respectively. The proposed method was applied to the analysis of target heavy metals in three kinds of cells (HepG2, Jurkat T and MCF7), and the recoveries for the spiked samples were in the range of 83.8%-117%. The extractable species of the target metals in cells were also studied and the results demonstrated a high selectivity of the developed methods towards free metal ions and/or their small molecular species.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Selective Separation and Preconcentration of trace Amounts of Gallium in Water and Rice Samples using Cloud Point Extraction and Determination by Inductively Coupled Plasma-Atomic Emission Spectrometry

In the present study a cloud-point extraction process using non-ionic surfactant Triton X-114 for selective extraction of gallium from aqueous solutions was developed. The method is based on the complex formation of Ga (III) with N, N′ -bis (salycilidene)-1, 2-phenylenediamine (salophen) as a chelating agent in buffer media of pH 5. After phase separation and dilution of the surfactant-rich pha...

متن کامل

Review of preconcentration and solid phase extraction for the determination of trace Lead

Spectrometric techniques for the analysis of trace lead have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, and considers the features of the application with several spectrometric techniques. The use of an appropriate sample handling technique is a...

متن کامل

Review of preconcentration and solid phase extraction for the determination of trace Lead

Spectrometric techniques for the analysis of trace lead have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, and considers the features of the application with several spectrometric techniques. The use of an appropriate sample handling technique is a...

متن کامل

Trace determination of gatifloxacin in pharmaceutical and biological samples using hydrophobic magnetic nanoparticles-assisted ionic liquid microextraction coupled with spectrofluorimetry

A simple and rapid microextraction procedure based on the application of magnetic nanoparticles and hydrophobic 1-Hexylpyridinium hexafluorophosphate [Hpy][PF6] ionic liquid (IL) was applied to trace determination of gatifloxacin. A mixture of [Hpy][PF6] and magnetic nanoparticles was injected into the sample solution containing the analyse of interest and a cloudy solution was forme...

متن کامل

Trace determination of gatifloxacin in pharmaceutical and biological samples using hydrophobic magnetic nanoparticles-assisted ionic liquid microextraction coupled with spectrofluorimetry

A simple and rapid microextraction procedure based on the application of magnetic nanoparticles and hydrophobic 1-Hexylpyridinium hexafluorophosphate [Hpy][PF6] ionic liquid (IL) was applied to trace determination of gatifloxacin. A mixture of [Hpy][PF6] and magnetic nanoparticles was injected into the sample solution containing the analyse of interest and a cloudy solution was forme...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Analyst

دوره 140 16  شماره 

صفحات  -

تاریخ انتشار 2015