Thalamic nuclei segmentation in clinical 3T T1-weighted Images using high-resolution 7T shape models

نویسندگان

  • Yuan Liu
  • Pierre-François D'Haese
  • Allen T. Newton
  • Benoit M. Dawant
چکیده

Accurate and reliable identification of thalamic nuclei is important for surgical interventions and neuroanatomical studies. This is a challenging task due to their small sizes and low intra-thalamic contrast in standard T1-weighted or T2weighted images. Previously proposed techniques rely on diffusion imaging or functional imaging. These require additional scanning and suffer from the low resolution and signal-to-noise ratio in these images. In this paper, we aim to directly segment the thalamic nuclei in standard 3T T1-weighted images using shape models. We manually delineate the structures in high-field MR images and build high resolution shape models from a group of subjects. We then investigate if the nuclei locations can be inferred from the whole thalamus. To do this, we hierarchically fit joint models. We start from the entire thalamus and fit a model that captures the relation between the thalamus and large nuclei groups. This allows us to infer the boundaries of these nuclei groups and we repeat the process until all nuclei are segmented. We validate our method in a leave-one-out fashion with seven subjects by comparing the shape-based segmentations on 3T images to the manual contours. Results we have obtained for major nuclei (dice coefficients ranging from 0.57 to 0.88 and mean surface errors from 0.29mm to 0.72mm) suggest the feasibility of using such joint shape models for localization. This may have a direct impact on surgeries such as Deep Brain Stimulation procedures that require the implantation of stimulating electrodes in specific thalamic nuclei.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultra-high field upper extremity peripheral nerve and non-contrast enhanced vascular imaging

OBJECTIVE The purpose of this study was to explore the efficacy of Ultra-high field [UHF] 7 Tesla [T] MRI as compared to 3T MRI in non-contrast enhanced [nCE] imaging of structural anatomy in the elbow, forearm, and hand [upper extremity]. MATERIALS AND METHOD A wide range of sequences including T1 weighted [T1] volumetric interpolate breath-hold exam [VIBE], T2 weighted [T2] double-echo stea...

متن کامل

Development and Evaluation of an Algorithm for the Computer-Assisted Segmentation of the Human Hypothalamus on 7-Tesla Magnetic Resonance Images

Post mortem studies have shown volume changes of the hypothalamus in psychiatric patients. With 7T magnetic resonance imaging this effect can now be investigated in vivo in detail. To benefit from the sub-millimeter resolution requires an improved segmentation procedure. The traditional anatomical landmarks of the hypothalamus were refined using 7T T1-weighted magnetic resonance images. A detai...

متن کامل

T1 contrast in the human brain at 7 Tesla

Introduction: MRI in humans at ultra-high field offers not only high baseline sensitivity but also interesting contrast behavior. Compared to lower field strength T1 relaxation times generally increase but seem to remain highly diverse, promising strong T1 contrast especially in brain imaging. Exploring this potential is mainly hampered by the non-uniformity of the transmit RF fields generate b...

متن کامل

Double Acquisition Background Suppressed (DABS) FAIR at 3T and 7T: advantages for simultaneous BOLD and CBF acquisition

DABS (B); 7T BOLD images using DABS at 3 mm isotropic resolution (C) and 1.5x1.5x3 mm (D). 3T perfusion weighted (PW) images at 3 mm isotropic resolution using standard FAIR (E) and with DABS (F); 7T PW images DABS 3 mm isotropic resolution (G) and 1.5x1.5x3 mm (H). All images have overlaid activated regions. Double Acquisition Background Suppressed (DABS) FAIR at 3T and 7T: advantages for simu...

متن کامل

Validation Of A Thalamus Segmentation Based On Local Difusion Information

Introduction: Fast and accurate segmentation of thalamic nuclei is important for clinical applications such as treatment of Parkinson's disease or chronic pain syndrome for example. The intrinsic contrast in standard anatomical MR images in the thalamus is very low, therefore direct segmentation of thalamic nuclei is not possible. Since thalamic nuclei have a distinct and well-ordered fiber str...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015