Iodinated contrast opacification gradients in normal coronary arteries imaged with prospectively ECG-gated single heart beat 320-detector row computed tomography.

نویسندگان

  • Michael L Steigner
  • Dimitrios Mitsouras
  • Amanda G Whitmore
  • Hansel J Otero
  • Chunliang Wang
  • Orla Buckley
  • Noah A Levit
  • Alia Z Hussain
  • Tianxi Cai
  • Richard T Mather
  • Orjan Smedby
  • Marcelo F DiCarli
  • Frank J Rybicki
چکیده

BACKGROUND To define and evaluate coronary contrast opacification gradients using prospectively ECG-gated single heart beat 320-detector row coronary angiography (CTA). METHODS AND RESULTS Thirty-six patients with normal coronary arteries determined by 320 x 0.5-mm detector row coronary CTA were retrospectively evaluated with customized image postprocessing software to measure Hounsfield Units at 1-mm intervals orthogonal to the artery center line. Linear regression determined correlation between mean Hounsfield Units and distance from the coronary ostium (regression slope defined as the distance gradient G(d)), lumen cross-sectional area (G(a)), and lumen short-axis diameter (G(s)). For each gradient, differences between the 3 coronary arteries were analyzed with ANOVA. Linear regression determined correlations between measured gradients, heart rate, body mass index, and cardiac phase. To determine feasibility in lesions, all 3 gradients were evaluated in 22 consecutive patients with left anterior descending artery lesions > or =50% stenosis. For all 3 coronary arteries in all patients, the gradients G(a) and G(s) were significantly different from zero (P<0.0001), highly linear (Pearson r values, 0.77 to 0.84), and had no significant difference between the left anterior descending, left circumflex, and right coronary arteries (P>0.503). The distance gradient G(d) demonstrated nonlinearities in a small number of vessels and was significantly smaller in the right coronary artery when compared with the left coronary system (P<0.001). Gradient variations between cardiac phases, heart rates, body mass index, and readers were low. Gradients in patients with lesions were significantly different (P<0.021) than in patients considered normal by CTA. CONCLUSIONS Measurement of contrast opacification gradients from temporally uniform coronary CTA demonstrates feasibility and reproducibility in patients with normal coronary arteries. For all patients, the gradients defined with respect to the coronary lumen cross-sectional area and short-axis diameters are highly linear, not significantly influenced by the coronary artery (left anterior descending artery versus left circumflex versus right coronary artery), and have only small variation with respect to patient parameters. Preliminary evaluation of gradients across coronary artery lesions is promising but requires additional study.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Iodinated Contrast Opacification Gradients in Normal Coronary Arteries Imaged with Prospectively ECG-Gated Single Heart Beat 320-Detector Row Computed Tomography Steigner;Normal Coronary CT Contrast Gradients

Background: To define and evaluate coronary contrast opacification gradients using prospectively ECG-gated single heart beat 320-detector row coronary angiography (CTA). Methods and Results: Thirty-six patients with normal coronary arteries determined by 320 x 0.5 mm detector row coronary CTA were retrospectively evaluated with customized image postprocessing software to measure Hounsfield Unit...

متن کامل

Correction: Feasibility of Low-Dose Contrast Medium High Pitch CT Angiography for the Combined Evaluation of Coronary, Head and Neck arteries

PURPOSE To evaluate the image quality and radiation dose of combined heart, head, and neck CT angiography (CTA) using prospectively electrocardiography (ECG)-triggered high-pitch spiral scan protocol, compared with single coronary CTA. MATERIALS AND METHODS 151 consecutive patients were prospectively included and randomly divided into three groups. Group 1 (n = 47) underwent combined heart, n...

متن کامل

Recent Update on Radiation Dose Assessment for the State-of-the-Art Coronary Computed Tomography Angiography Protocols

OBJECTIVES This study aimed to measure the absorbed doses in selected organs for prospectively ECG-triggered coronary computed tomography angiography (CCTA) using five different generations CT scanners in a female adult anthropomorphic phantom and to estimate the effective dose (HE). MATERIALS AND METHODS Prospectively ECG-triggered CCTA was performed using five commercially available CT scan...

متن کامل

Influence of image acquisition settings on radiation dose and image quality in coronary angiography by 320-detector volume computed tomography: the CORE320 pilot experience

The objective of this study was to investigate the impact of image acquisition settings and patients' characteristics on image quality and radiation dose for coronary angiography by 320-row computed tomography (CT). CORE320 is a prospective study to investigate the diagnostic performance of 320-detector CT for detecting coronary artery disease and associated myocardial ischemia. A run-in phase ...

متن کامل

Triple-rule-out CT angiography for evaluation of acute chest pain and possible acute coronary syndrome.

Triple-rule-out (TRO) computed tomographic (CT) angiography can provide a cost-effective evaluation of the coronary arteries, aorta, pulmonary arteries, and adjacent intrathoracic structures for the patient with acute chest pain. TRO CT is most appropriate for the patient who is judged to be at low to intermediate risk for acute coronary syndrome (ACS) and whose symptoms may also be attributed ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation. Cardiovascular imaging

دوره 3 2  شماره 

صفحات  -

تاریخ انتشار 2010