Design of the Jupiter Accelerator for Large X-ray Yields

نویسنده

  • Juan J. Ramirez
چکیده

Nanosecond Pulsed Power provides the unique capability to deliver high energy and high power at low cost and high efficiency. One important application of this technology is to the generation of intense, highenergy laboratory X-ray sources using magnetically driven implosions. Saturn generates ~500 kilojoules of x-rays using this process. This paper presents a detailed design concept for a ~15 MJ laboratory X-ray source and discusses the resultant capabilities for high energy density physics studies.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Shielding simulations for safe use of curtain electron accelerator by MCNP4C

In an electron curtain accelerator, when the electron beam passes through the titanium exit window of the accelerator chamber, X-ray photons are produced as a negative by-product of retarding accelerated electrons. Controlling the produced X-ray photons to avoid their detrimental effects or in fact, proper shielding of the accelerator is an important issue that has to be considered in the use o...

متن کامل

بررسی تابش کانالی از ‌بلور‌های الماس به منظور تهیه پرتو X تک انرژی درشتاب دهنده خطی الکترون ELBE

The measurements of electron Channeling Radiation (CR) have been performed at ELBE linear electron accelerator of the Forschungszentrum Dresden-Rossendorf. The aim of performing these experiments was to optimize radiation yield and spectral line width of CR in order to apply channeling radiation for preparing a monochromatic X-ray source. Diamond crystals can be used in relatively high electron...

متن کامل

Monte Carlo Simulation of Electron Beams produced by LIAC Intraoperative Radiation Therapy Accelerator

Background: One of the main problems of dedicated IORT accelerators is to determine dosimetric characteristics of the electron beams. Monte Carlo simulation of IORT accelerator head and produced beam will be useful to improve the accuracy of beam dosimetry.Materials and Methods: Liac accelerator head was modeled using the BEAMnrcMonte Carlo simulation system. Phase-space files were generated at...

متن کامل

Protective and dosimeter design of the stationary and mobile model truck inspection system with electron linear accelerator radiation source

In this work, calculations of leaked dose from vehicle inspection area, the absorbed dose by driver and operator, and the required concrete thickness for shielding the inspection area are presented using the Monte Carlo code MCNPX2.6. The X-ray source of the present vehicle inspection system is a LinatronMi6 accelerator, end of which has only been simulated in this study (the electron beam coll...

متن کامل

Design, preparation and characterization of a novel BiFeO3/CuWO4 heterojunction catalyst for one-pot synthesis of trisubstituted imidazoles

In this work a novel heterojunction catalyst have been synthesized and employed as a highly efficient catalyst for one-pot synthesis of substituted imidazoles. Analytical methods including Fourier transform infrared (FT-IR), diffuse reflectance spectroscopy (DRS), X-ray diffraction (XRD), Energy- dispersive X-ray spectroscopy (EDX), Scanning electron microscopy (SEM) and Vibrating Sample Magnom...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1995