Protective Relay Setting of the Tie Line Tripping and Load Shedding for the Industrial Power System

نویسندگان

  • Chao-Shun Chen
  • Cheng-Ting Hsu
چکیده

This paper presents the proper underfrequency relay settings to enhance the operation of industrial power systems with cogeneration facilities. A cogeneration unit was installed in the plant in 1996 to supply the power demand of the plant. The cogeneration unit always faces the shutdown problem when a severe fault occurs on the nearby Taipower network. It is, therefore, necessary to investigate the plant protective relay settings to prevent a whole plant blackout when the contingency occurs. The transient stability analysis has been performed by considering both the detailed models of the cogenerators with the governor and exciter control systems and the external utility power system. The underfrequency relay settings for tie line tripping and load shedding are designed to prevent the tripping of the cogeneration units so that the electricity service to the critical loads of the industrial customer can be maintained in case serious external disturbances such as short circuit faults occur. In this study, the scheme of underfrequency relay settings has been developed for the power system of a large synthetic rubber manufacturer with a large cogeneration unit. Three study cases have been selected for the transient stability analysis to verify the effectiveness of the proposed protective relay setting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transient Stability Analysis of an Industrial Cogeneration System

The purpose of the paper is to analyze the transient stability of an industrial cogeneration system in Hsin-Chu Science-Based Industrial Park using ETAP software. The cogeneration system is installed two 161kV/161kV high-impendence transformers with tap-changer to connect with TPC for decreasing the short-circuit fault current and increasing the fault critical clearing time. The transient stabi...

متن کامل

حذف بار فرکانسی چندمرحله‌ای در سیستم توزیع جزیره‌‌شده

Disconnecting microgrid from main grid, may lead to severe frequency changes. Under frequency load shedding method provides a proper protection scheme by shedding certain amount of loads. Under frequency load shedding relay is used for frequency control of islanded microgrid. Each synchronous distributed generator (DG) of microgrid is equipped with a protective islanding detection device such a...

متن کامل

Optimal Setting Sor Under Frequency Load Shedding Relays Using Mixed Integer Linear Programming

After occurrence of some disturbances in power system that causes the sever imbalance between generation power and electrical load, the power system frequency begins to decrease. To prevent power system frequency instability and stop the frequency decay below the power system allowable frequency limitation, load shedding schemes should be utilized by applying under frequency load shedding relay...

متن کامل

Adaptive Setting of UFLS Relay Using Hourly Programming with Consideration of Renewable Energy Sources in Smart Grid

In the light of the emergence of smart grids, the functions associated with this type of grids in the blocks of the energy management system require the adoption of robust strategies in order to provide a higher level of control and protection. Under-frequency load shedding (UFLS) sheds load blocks when the frequency drop is below the threshold limit. In adaptive UFLS, in an advanced telecommun...

متن کامل

بهبود پایداری شبکه قدرت با روش جدید حذف بار ترکیبی

Power system blackouts have become a serious problem for electric utilities especially in recent years. Different forms of system instability have emerged in recent blackouts, such as voltage instability and frequency instability. To counteract each form of system instability, special algorithms have been designed in the protection system, e.g. Under Frequency Load Shedding (UFLS) and Under Vol...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000