Evaluation of the tacrolimus II microparticle enzyme immunoassay (MEIA II) in liver and renal transplant recipients.

نویسندگان

  • J L Cogill
  • P J Taylor
  • I S Westley
  • R G Morris
  • S V Lynch
  • A G Johnson
چکیده

We evaluated the MEIA II with blood samples with added tacrolimus (3.0, 5.0, 11.0, and 22.0 microg/L). The assay had acceptable recoveries (99-103%) and intraday imprecision (<16.0%) across the range of concentrations studied, except for the recoveries at 3.0 microg/L (86.3%) and 5.0 microg/L (80.7%). Comparison of liver (n = 116) and renal (n = 113) patient samples measured by MEIA II against HPLC-tandem mass spectrometry (HPLC-MS/MS) found a mean overestimation of 15.6%. From these comparison data it can be calculated that at values of 5 and 20 microLg/L in liver or renal transplant patient samples, measured by HPLC-MS/MS, MEIA II will have the corresponding range estimates of 3.6-7.9 microg/L and 20.9-25.4 microg/L, respectively. No clinically significant difference in results, in terms of overestimation or correlation, was observed between the two transplant groups studied. The MEIA II is an improvement on the previous MEIA I and is suitable for the therapeutic drug monitoring of tacrolimus where HPLC-MS/MS is unavailable.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of ELISA method versus MEIA method for daily practice in the therapeutic monitoring of tacrolimus.

BACKGROUND For the adequate management of transplant patients on tacrolimus therapy, it is important to obtain optimal blood concentrations. The purpose of this study was to determine the most appropriate method for daily practice of tacrolimus determination in whole blood. We compared enzyme-linked immunosorbent assay (ELISA) with microparticle enzyme immunoassay (MEIA), using European control...

متن کامل

False positive blood tacrolimus concentration in microparticle enzyme immunoassay.

The difference in the blood concentration of tacrolimus between the assay methods, microparticle enzyme immunoassay (MEIA) and enzyme linked immunosorbent assay (ELISA) was observed in a liver transplant recipient with anemia. MEIA provided significantly higher concentration than those of ELISA (7.8+/-1.9 vs. 5.0 +/- 1.8nglml, p<0.05) while the patient had low haematocrit <25%. The difference, ...

متن کامل

HPLC-microparticle enzyme immunoassay specific for tacrolimus in whole blood of hepatic and renal transplant patients.

Tacrolimus is a relatively new immunosuppressant used in organ transplantation to prevent graft rejection. However, its use is not devoid of side effects, making it important to maintain blood concentrations within therapeutic ranges. Several analytical methods are currently available for routine drug monitoring. However, these methods are based on use of the same monoclonal antibody, which als...

متن کامل

Low hematocrit and serum albumin concentrations underlie the overestimation of tacrolimus concentrations by microparticle enzyme immunoassay versus liquid chromatography-tandem mass spectrometry.

BACKGROUND Rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods are used increasingly for tacrolimus (TRL) monitoring but show a negative difference with respect to a microparticle immunoassay (MEIA). This report examines possible reasons for this difference between methods. METHODS We collected 1156 blood samples from 277 adult and 121 pediatric recipients of liver, renal,...

متن کامل

Determination of blood sirolimus concentrations in liver and kidney transplant recipients using the Innofluor® fluorescence polarization immunoassay: Comparison with the microparticle enzyme immunoassay and high-performance liquid chromatography-ultraviolet method

BACKGROUND Although high-performance liquid chromatography (HPLC) is the method of choice for blood sirolimus determination, the microparticle enzyme immunoassay (MEIA) run on the IMx analyser is widely used in therapeutic monitoring of this immunosuppressant agent. The aim of our study was to evaluate the possible determination of sirolimus using the fluorescence polarization immunoassay (FPIA...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 44 9  شماره 

صفحات  -

تاریخ انتشار 1998