Assessment of ventricular-arterial coupling with a model-based sensor

نویسندگان

  • Thomas Desaive
  • Bernard Lambermont
  • Alexandre Ghuysen
  • Philippe Kolh
  • Philippe Morimont
  • Pierre C. Dauby
  • Christina Starfinger
  • Christopher E. Hann
  • Geoffrey M. Shaw
  • J. Geoffrey Chase
چکیده

Estimation of ventricular contractility is clinically important in diagnosing cardiac dysfunction in the critically ill. However, experimental assessment of indexes of ventricular contractility, such as the end-systolic pressure-volume relationship requires a highly invasive maneuver. This research describes the use of a previously validated cardiovascular system (CVS) model and identification process to evaluate the right-ventricle contractility as well as the right ventricular arterial coupling in septic shock. The results show good agreement with the gold-standard experimental assessment (conductance catheter method), and offer the potential to develop a model-based sensor to monitor the coupling in clinical realtime.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of ventricular contractility and ventricular-arterial coupling with a model-based sensor

Estimation of ventricular contractility and ventricular arterial coupling is clinically important in diagnosing and treating cardiac dysfunction in the critically ill. However, experimental assessment of indexes of ventricular contractility, such as the end-systolic pressure-volume relationship, requires a highly invasive maneuver and measurements that are not typical in an intensive care unit ...

متن کامل

Normal Value of Left Ventricular End-Systolic Elastance in Infants and Children

Background: In certain conditions, there is a need for a specific and improved measure of cardiac performance.  Routine methods for assessing left ventricular (LV) function are based on image-analysis or right heart monitoring which do not allow evaluation of ventriculo-arterial interaction. Chen et al presented a noninvasive method allowing measurement of end-systolic pressure–volume relation ...

متن کامل

Geographic and Clustering Routing for Energy Saving in Wireless Sensor Network with Pair of Node Groups

Recently, wireless sensor network (WSN) is the popular scope of research. It uses too many applications such as military and non-military. WSN is a base of the Internet of Things (IoT), pervasive computing. It consists of many nodes which are deployed in a specific filed for sense and forward data to the destination node. Routing in WSN is a very important issue because of the limitation of the...

متن کامل

Simulation and Modeling of a High Sensitivity Micro-electro-mechanical Systems Capacitive Pressure Sensor with Small Size and Clamped Square Diaphragm

This paper proposes a Micro-electro-mechanical (MEMS) capacitive pressure sensor that relies on the movable electrode displaced like a flat plate equal to the maximum center deflection of diaphragm. The diaphragm, movable electrode and mechanical coupling are made of polysilicon, gold and Si3N4, respectively. The fixed electrode is gold and the substrate is Pyrex glass. This proposed method inc...

متن کامل

Acute and chronic ventricular-arterial coupling in systole and diastole: insights from an elderly hypertensive model.

Aging and hypertension lead to arterial remodeling and tandem increases in arterial (Ea) and ventricular (LV) systolic stiffness (ventricular-arterial [VA] coupling). Age and hypertension also predispose to heart failure with normal ejection fraction (HFnlEF), where symptoms during hypertensive urgencies or exercise are common. We hypothesized that: (1) chronic VA coupling also occurs in diasto...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010