VLSI Architecture of Digital Auditory Filter for Speech Processor of Cochlear Implant
نویسندگان
چکیده
Digital VLSI implementation of an auditory filter for speech processor of cochlear implant (CI) is proposed. Optimized design for hardware implementation of the filter with respect to area, power and speed is the significant criterion for the implementation of auditory filter for a CI. A digital filter is designed using the System Generator10.1 through the mathematical model of the FIR filter developed in Simulink using FDA tool. It is further downloaded onto the Spartan 3E FPGA Kit. Translation of the Simulink model into a hardware realization is done using system generator. Thus simulation is done both in the hardware and software environment. VHDL code for the filter is developed using the coefficients generated from FDA tool of System generator. The area, power and delay analysis for the design is done using SYNOPSYS Design Vision tool with 180micron technology. General Terms Auditory filter, VLSI Signal Processing,
منابع مشابه
Evaluation of the Slope of Amplitude Growth Function Changes of the Electrically Evoked Action Potential in Three Months after Receiving the Device in Children with Cochlear Implant
Objective: In neural response telemetry, intracochlear electrodes stimulate the auditory nerve and record the neural responses. The electrical stimulation is sent to the auditory nerve by an electrode and the resulted response, called electrically evoked compound action potential, is recorded by an adjacent electrode. The most important clinical applications of this test are evaluation and moni...
متن کاملRelationship between Electrically Evoked Compound Action Potential Thresholds and Auditory, Language, and Speech Progress after Cochlear Implant Surgery
Introduction: Electrically evoked compound action potential (ECAP) is an objective auditory response that can be used in the programing of cochlear implants. The aims of this study were to monitor ECAP thresholds and auditory, language and speech progress for 6 months after cochlear implant surgery and to evaluate any relationship between them. Materials and Methods: Ten children with a m...
متن کاملRelationship between Working Memory, Auditory Perception and Speech Intelligibility in Cochlear Implanted Children of Elementary School
Objectives: This study examined the relationship between working and short-term memory performance, and their effects on cochlear implant outcomes (speech perception and speech production) in cochlear implanted children aged 7-13 years. The study also compared the memory performance of cochlear implanted children with their normal hearing peers. Methods: Thirty-one cochlear impl...
متن کاملAuditory Perception and Verbal Intelligibility in Children with Cochlear Implant, Hearing Aids and Normal Hearing
Objective: The aim of the present research was to compare the auditory perception and verbal intelligibility in children with cochlear implant, hearing aids and normal hearing. Methods: 60 children aged 5-7 years were divided to three groups and each group contained 20 children. The first and second groups were selected ordinarily from children with cochlear implant and hearing aids by conve...
متن کاملبررسی اثر فیدبک شنوائی در تولید گفتار بعد از عمل کوکلئار ایمپلنت
The main goal of this study is to determine the auditory feedback effects in improvement of speech production process in prelingual totally deaf children who used cochlear implant prosthesis. For this reason, we recorded speech of four prelingual cochlear implant children pre and post of operation. Then we extract some static features of vowels-such as fundamental frequency, formant frequencies...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2012