Inter-study reproducibility of 3D volume selective fast spin echo sequence for quantifying carotid artery wall volume in asymptomatic subjects.

نویسندگان

  • A Varghese
  • L A Crowe
  • R H Mohiaddin
  • P D Gatehouse
  • G Z Yang
  • D N Firmin
  • D J Pennell
چکیده

PURPOSE To determine, in asymptomatic subjects, the inter-study reproducibility of a three-dimensional (3D) volume selective fast spin echo (FSE) cardiovascular magnetic resonance sequence for the assessment of carotid artery wall volume as a measure of atheroma burden. METHODS Inter-study reproducibility was evaluated in 16 asymptomatic volunteers (10 male, 6 female). Both carotid arteries were scanned twice with a median inter-scan time of 5 days. The images were acquired in cross-section, and the total carotid arterial wall volume (TWV) was calculated by subtraction of the total carotid lumen volume from the total outer carotid vessel volume. RESULTS The mean carotid T1-weighted TWV for the first and second scans was 828 and 821 mm(3), respectively (mean difference 7 mm(3), p=0.45). The standard deviation (S.D.) of the differences between the measurements was 38 mm(3) yielding an inter-study coefficient of variation of 4.6%. The time for each study was approximately 30 min. For the longitudinal evaluation of carotid atheroma burden with pharmacological intervention versus placebo, 32 subjects would enable a difference of 38 mm(3) to be detected with a significance level of 5% with 80% power. CONCLUSION Volumetric analysis with carotid CMR in asymptomatic subjects using a 3D volume-selective FSE is time-efficient with good inter-study reproducibility, and is well suited for longitudinal studies of carotid atheroma with reasonable sample sizes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interstudy reproducibility of three-dimensional volume-selective fast spin echo magnetic resonance for quantifying carotid artery wall volume.

PURPOSE To assess the interstudy reproducibility of a three-dimensional volume-selective, fast spin echo (FSE) magnetic resonance technique for the assessment of carotid artery wall volume, which is a marker for total carotid plaque volume. MATERIALS AND METHODS Interstudy reproducibility was evaluated in 10 subjects with evidence of carotid artery atherosclerotic disease on carotid Doppler u...

متن کامل

Volume-selective 3D turbo spin echo imaging for vascular wall imaging and distensibility measurement.

PURPOSE To use a volume-selective 3D turbo spin echo (TSE) technique to image the carotid artery wall and measure distensibility. MATERIALS AND METHODS A high-resolution volume-selective 3D TSE sequence has been developed. Volume selection is accomplished by orthogonal gradients for the 90 degrees and 180 degrees excitations and allows a 3D volume of vessel wall to be imaged in a relatively s...

متن کامل

Reproducibility of coronary vessel wall imaging techniques

Background Coronary wall thickness measurements must be highly reproducible to be useful in longitudinal studies. While 2D turbo-spin-echo (TSE) and spiral techniques are commonly used, 3D techniques reduce partial-volume effects and allow greater vessel coverage. Recently, 3D coronary wall imaging was demonstrated with 100% respiratory efficiency (RE) using beat-to-beat respiratory motion corr...

متن کامل

Vessel-wall imaging and quantification of flow-mediated dilation using water-selective 3D SSFP-echo

BACKGROUND To introduce a new, efficient method for vessel-wall imaging of carotid and peripheral arteries by means of a flow-sensitive 3D water-selective SSFP-echo pulse sequence. METHODS Periodic applications of RF pulses will generate two transverse steady states, immediately after and before an RF pulse; the latter being referred to as the SSFP-echo. The SSFP-echo signal for water protons...

متن کامل

Reproducibility of black-blood coronary vessel wall MR imaging.

PURPOSE New magnetic resonance imaging (MRI) methods can provide high spatial resolution images of the coronary artery wall, and statistically significant differences in coronary vessel wall thickness between atherosclerotic disease patients and control subjects have been shown. The aim of this study is to assess inter-study reproducibility (i.e., repeatability) of the cross-sectional 2D corona...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Atherosclerosis

دوره 183 2  شماره 

صفحات  -

تاریخ انتشار 2005