Improved efficiency for respiratory motion compensation in three-dimensional flow measurements

نویسندگان

  • Mehmet Akcakaya
  • Praveen Gulaka
  • Tamer A Basha
  • Thomas H Hauser
  • Warren J Manning
  • Reza Nezafat
چکیده

Background Phase contrast (PC) CMR is clinically used for in-vivo assessment of blood flow in cardiovascular disease [1]. Typically, a through-plane 2D acquisition is performed for evaluating the blood flow. Recently, 3D time-resolved PC CMR has been used for quantification and visualization of the blood flow in all three directions of a volume [2]. However, such acquisitions require long scan times, which are further prolonged by the need for respiratory motion compensation, typically using respiratory navigators. In this study, we hypothesized that respiratory gating the center of k-space only will yield similar measurements to a fully respiratory-gated acquisition, since the phase information is mainly coming from the central k-space, and evaluated these two gating approaches.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Free-breathing phase contrast MRI with near 100% respiratory navigator efficiency using k-space-dependent respiratory gating.

PURPOSE To investigate the efficacy of a novel respiratory motion scheme, where only the center of k-space is gated using respiratory navigators, versus a fully respiratory-gated acquisition for three-dimensional flow imaging. METHODS Three-dimensional flow images were acquired axially using a gradient echo sequence in a volume, covering the ascending and descending aorta, and the pulmonary a...

متن کامل

Advanced Motion Correction Methods in PET

With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...

متن کامل

Advanced Respiratory Motion Compensation for Coronary MR Angiography

Despite technical advances, respiratory motion remains a major impediment in a substantial amount of patients undergoing coronary magnetic resonance angiography (CMRA). Traditionally, respiratory motion compensation has been performed with a one-dimensional respiratory navigator positioned on the right hemi-diaphragm, using a motion model to estimate and correct for the bulk respiratory motion ...

متن کامل

Impact of Various Image Reconstruction Methods on Joint Compensation of Respiratory Motion and Partial Volume Effects in Whole-Body 18F-FDG PET/CT Imaging: Patients with Non-Small Cell Lung Cancer

Background: The present study aims to assess the impact of various image reconstruction methods in 18F-FDG PET/CT imaging on the quantification performance of the proposed technique for joint compensation of respiratory motion and partial volume effects (PVEs) in patients with non-small cell lung cancer. Materials and Methods: An image-based deconvolution technique was proposed, incorporating w...

متن کامل

Advances in 4D Gated Cardiac PET Imaging for Image Quality Improvement and Cardiac Motion and Contractility Estimation

Quantitative four-dimensional (4D) image reconstruction methods with respiratory and cardiac motion compensation are an active area of research in ECT imaging, including SPECT and PET. They are the extensions of three-dimensional (3D) statistical image reconstruction methods with iterative algorithms that incorporate accurate models of the imaging process and provide significant improvement in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2013