Value of electrical impedance scanning (EIS) in the evaluation of BI-RADS III/IV/V-lesions.
نویسندگان
چکیده
Two hundred and fifty-six (256) patients (72% preoperative, 28% pre-Mammotome) were prospectively examined with EIS using the TS 2000 (TransScan Research and Development Center, Israel; temporarily distributed by Siemens, Erlangen) with the "LOS"-software (level of suspicion). All exams were performed with the targeted scan probe, the observer knowing all clinical and imaging facts. The area of the lesions was examined with EIS at least with 5 single scans. The evaluation included a scaling of lesions from 1 (surely benign) up to 5 (highly suggestive for malignancy) as well as the additional notification of spots. Results of EIS were based upon the automatic scaling which is provided by the software and were compared with mammography and histology. Furthermore the influence of the histology, size of lesions, and presence/absence of spots on the EIS results were analyzed. Histology revealed benign results in 138 lesions and malignant results in 118 lesions (DCIS=61, ID-Ca=51, IL-Ca=5, mucinous Ca=1). Mammography as expected yielded high values with 91% sensitivity and 62% specificity. Overall sensitivity of EIS was 75.4%, specificity 42.03%, negative predictive value 66.7% and positive predictive value 52.7% (89 TP, 58 TN, 80 FP, 29 FN). EIS was false negative in 20 ID-Ca, 3 IL-Ca, 1 IDL-Ca, 4 DCIS, and 1 mucinous carcinoma. Sensitivity and specificity of EIS did not differ for the different histological differentiations neither for the degree of invasion. Also the additional notification of "spots" didn't show a correlation to malignancy. There were significant differences of the sensitivity of EIS regarding the tumor size. While EIS correctly diagnosed 85% of lesions <10 mm in size, only 64% of lesions >10 mm were detected. Most frequent lesion types for false positives were mastopathy (55/80 FP) and fibroadenoma (21/80 FP). Patient acceptance of EIS was perfect and there were no drop outs because of movement artifacts. In conclusion the "LOS"-software clearly improved the clinical performance of the TS 2000 as compared to the initial software. The high sensitivity of EIS in small cancers which was found in our study may indicate an advantage of this method. However, the overall sensitivity and specificity with this setup of EIS is still far too low. Further improvements especially including the measurement of higher frequencies should be realized.
منابع مشابه
Breast Diagnosis: Concordance Analysis Between the BI-RADS Classification and Tsukuba Sonoelastography Score
AIMS To establish the correlations between the ultrasound (US) BI-RADS classification and Tsukuba elastography score when assessing breast lesions. To determine which type of breast lesion (BI-RADS category) would benefit most from an elastographic assessment. PATIENTS AND METHODS The investigated sample of imaging comprised a number of 129 images belonging to 92 subjects examined with a Hita...
متن کاملRelationship between BI-RADS 4 Ultrasound Index and Pathological Findings and Clinical Outcomes in Breast Lesions
Introduction: breast cancer is listed as the most common type of cancer in women and many patients suffer from this disease worldwide. However, the timely diagnosis of the condition can lower the rate of mortality and morbidity. Breast imaging-reporting and data system (BI-RADS) is a noninvasive scoring system. The aim of our study was to assess the BI-RADS for patients and evaluate the corresp...
متن کاملReview Article: Application of Electrical Impedance Spectroscopy in Bladder Cancer Screening
Introduction Bladder cancer is the most common malignancy in elderly people and most bladder cancers are transitional cell carcinomas (TCC). Bladder pathology is usually investigated visually by cystoscopy and this technique can represent different conditions ranging from simple inflammation to flat CIS. However, biopsies must be taken from the suspected area to obtain diagnostic information. T...
متن کاملThe impact of lesion vascularisation on tumours detection by electrical impedance scanning at 200 Hz
OBJECTIVE Cancer cells exhibit altered local dielectric properties compared to normal cells. These properties are measurable as a difference in electrical conductance using electrical impedance scanning (EIS). EIS is at present not sufficiently accurate for clinical routine despite its technological advantages. To modify the technology and increase its accuracy, the factors that influence preci...
متن کاملEvaluation of electrical impedance spectroscopy as an adjunct to dermoscopy in short-term monitoring of atypical melanocytic lesions
BACKGROUND Early detection of melanoma is vital for treatment outcome and survival. Short-term sequential digital dermoscopic monitoring (ST-SDDM) involves the capture and assessment of dermoscopic images of one or more atypical melanocytic lesions (AMLs), at baseline and after four months, in order to detect early morphologic changes. Electrical impedance spectroscopy (EIS) is a diagnostic too...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Technology in cancer research & treatment
دوره 4 1 شماره
صفحات -
تاریخ انتشار 2005