A fast fiducial marker tracking model for fully automatic alignment in electron tomography

نویسندگان

  • Renmin Han
  • Fa Zhang
  • Xin Gao
چکیده

Motivation Automatic alignment, especially fiducial marker-based alignment, has become increasingly important due to the high demand of subtomogram averaging and the rapid development of large-field electron microscopy. Among the alignment steps, fiducial marker tracking is a crucial one that determines the quality of the final alignment. Yet, it is still a challenging problem to track the fiducial markers accurately and effectively in a fully automatic manner. Results In this paper, we propose a robust and efficient scheme for fiducial marker tracking. Firstly, we theoretically prove the upper bound of the transformation deviation of aligning the positions of fiducial markers on two micrographs by affine transformation. Secondly, we design an automatic algorithm based on the Gaussian mixture model to accelerate the procedure of fiducial marker tracking. Thirdly, we propose a divide-and-conquer strategy against lens distortions to ensure the reliability of our scheme. To our knowledge, this is the first attempt that theoretically relates the projection model with the tracking model. The real-world experimental results further support our theoretical bound and demonstrate the effectiveness of our algorithm. This work facilitates the fully automatic tracking for datasets with a massive number of fiducial markers. Availability and implementation The C/C ++ source code that implements the fast fiducial marker tracking is available at https://github.com/icthrm/gmm-marker-tracking. Markerauto 1.6 version or later (also integrated in the AuTom platform at http://ear.ict.ac.cn/) offers a complete implementation for fast alignment, in which fast fiducial marker tracking is available by the '-t' option. Contact [email protected]. Supplementary information Supplementary data are available at Bioinformatics online.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Fully Automatic Alignment of Electron Tomography Images without Fiducial Markers

In structural biology, electron tomography is used in reconstructing three-dimensional objects such as macromolecules, viruses, and cellural organelles to learn their structure and properties. In order to successfully perform the three-dimensional reconstruction from a series of transparent two-dimensional images, the images have to be aligned or registered. In this paper, we propose a multi-ph...

متن کامل

On the Alignment of Transmission Electron Microscope Images without Fiducial Markers

Accurate image alignment is needed for computing three-dimensional reconstructions from transmission electron microscope tilt series. So far, the best alignment results have been obtained by using colloidal gold beads as fiducial markers. If their use has not been possible for some reason, the only option has been the automatic 2D-crosscorrelation-based registration methods. However, since the ...

متن کامل

Automatic alignment of transmission electron microscope tilt series without fiducial markers.

Accurate image alignment is needed for computing three-dimensional reconstructions from transmission electron microscope tilt series. So far, the best results have been obtained by using colloidal gold beads as fiducial markers. If their use has not been possible for some reason, the only option has been the automatic cross-correlation-based registration methods. However, the latter methods are...

متن کامل

Markov random field based automatic image alignment for electron tomography.

We present a method for automatic full-precision alignment of the images in a tomographic tilt series. Full-precision automatic alignment of cryo electron microscopy images has remained a difficult challenge to date, due to the limited electron dose and low image contrast. These facts lead to poor signal to noise ratio (SNR) in the images, which causes automatic feature trackers to generate err...

متن کامل

Fully Automatic Head Motion Correction for Interventional C-arm Systems using Fiducial Markers

Today, an angiographic C-arm CT system is standard in most interventional laboratories and 3-D imaging in the interventional suite has become common. Due to the longer acquisition time of a C-arm system, of up to several seconds, intra-scan patient motion is a problem. In this paper, a fully automatic motion estimation and compensation framework utilizing fiducial markers is presented to mitiga...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Bioinformatics

دوره 34 5  شماره 

صفحات  -

تاریخ انتشار 2018