TRiP98: Parallelization of Dose Calculation

نویسندگان

  • J. Trautmann
  • W. Heenes
  • G. Kraft
  • M. Krämer
چکیده

TRiP98, a treatment planning program, was used in the pilot project of heavy ion radiotherapy with scanned ion beams at GSI [1]. Over 400 patients were treated from 1997 to 2008 [2]. Currently TRiP98 is used for research purposes. One big part of the actual research is to make TRiP98 able to handle 4D data sets [3]. This is needed for the treatment of moving tumors (like lung tumors). Due to this development of TRiP98 and the therefore growing amount of data, the need of being able to calculate data faster is becoming more and more important. In this approach we focus on the dose calculation of the standard TRiP98 version. In total five different algorithms have to be considered: three for the absorbed dose and two for the biological dose [4]. The aim of the work done here is to show that parallel dose calculation is working. In further steps, this approach could be used as a basis for an implementation in the new 4D developments or even for other parts of TRiP98 such as dose optimization.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental validation of survival calculations in the presence of motion

The software TRiP98 [1] is successfully used at GSI for treatment planning of stationary tumors. It is capable to calculate the absorbed dose and the biologically effective dose resulting from the superposition of usually several thousand C-12 pencil beams. Treatment is delivered with the raster scanner system [2]. If the target is subject to respiratory motion, treatment is not yet possible be...

متن کامل

Treatment Planning for the Carbon Ion Radiotherapy

In the three therapy beam times 2007 about 50 patients were planned and treated with our treatment planning software, TRiP98, and its development version, TRiP98BEAM. In the past, the standard method was to optimize the biological target dose distribution for the contributing partial fields singly. Due to the enormous effort for the computation of biological effects, only a simple, but still su...

متن کامل

Optimized Parallelization for Nonlocal Means Based Low Dose CT Image Processing

Low dose CT (LDCT) images are often significantly degraded by severely increased mottled noise/artifacts, which can lead to lowered diagnostic accuracy in clinic. The nonlocal means (NLM) filtering can effectively remove mottled noise/artifacts by utilizing large-scale patch similarity information in LDCT images. But the NLM filtering application in LDCT imaging also requires high computation c...

متن کامل

Minimization-Algorithms for Biological Multiple Field Optimization

The software TRiP98 [1, 2, 3] is successfully used for patient treatment planning in the GSI pilot project. A crucial part of the treatment planning is the particle number optimization. The main goal of optimization is to achieve a target dose distribution as close as possible to the prescribed biological dose distribution. Multiple field optimization (MFO) allows a better target conformity and...

متن کامل

Status of 4D Treatment Planning Implementations for TRiP98

TRiP98 is a treatment planning program for radiotherapy with scanned ion beams. It was developed at GSI and has been successfully used in clinical routine from 1997-2008 for over 400 patients, predominantly with head and neck tumors [1,2]. The treatment of tumors within moving organs, such as lung tumors, with scanned ion beams involves additional complexity of the beam delivery and the treatme...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011