Test of reliability of echocardiographic estimation of left ventricular dimensions and volumes.
نویسندگان
چکیده
This test is based on the incompressibility of myocardium, which dictates that left ventricular wall volume remains constant throughout the cardiac cycle. The volumes occupied by the left ventricular cavity, by ventricular wall plus cavity, and hence by ventricular wall alone were estimated, both at end-systole and at end-diastole, from ecocardiographic measurements of cavity transverse dimension and wall thickness. Wall volumes were determined by assuming an ellipsoid shape (the major axis being predicted from aggression equations relating angiocardiographic and echocardiographic cavity dimensions) and also by the cube method. A discrepancy between systolic and diastolic wall volume estimates indicates either that the measurements of ventricular dimensions were unreliable or that the assumptions of ventricular geometry involved in the volume calculations were incorrect. Studies were made on 60 subjects. Using the ellipsoid formula, values for wall volume ranged from 66 to 719 ml; systolic and diastolic wall volumes correlated closely (r = 0-96, mean difference = 6-8 +/- 0-9 (SEM) %) supporting the reliability of the echocardiographic dimensions and estimates of cavity and wall volume. In the 12 patients with very large end-diastolic cavity transverse dimensions (6-5 to 8-6 cm) however, correlation was less good (r - 0-81, mean difference = 14-3 +/- 2-3 (SEM) 5). Using the cube method, which does not allow for the changing relation between minor and major cavity axes with increasing cavity size, wall volumes were greater (76 to 986 ml) but correlation was similar (r = 0-94, mean difference = 7-1 +/- 0-9 (SEM)%). Having established that it is possible to obtain close agreement between wall volumes determined at different points in the cardiac cycle, this test can be used to assess the reliability of echocardiographic left ventricular dimensions and volume estimates in individual subjects.
منابع مشابه
Reference values of M-mode echocardiographic parameters and indices in conscious Labrador Retriever dogs
Breed-wise standard echocardiographic values in dogs have been reported as there is variation in body and chest conformation which limits the application of data of one breed for other breed. Labrador Retrievers being originated from hunting dogs, might have different echocardiographic values from standard normal range of other dog breeds. So, the present study was aimed to determine the M-mode...
متن کاملAORTO-LEFT VENTRICULAR TUNNEL. A CASE REPORT WITH AORTIC PRESSURE AND ECHOCARDIOGRAPHIC FINDINGS
A seven-year-old girl with clinical diagnosis of aortic insufficiency underwent echocardiographic and hemodynamic evaluation and referred for surgery with the same diagnosis. However, at surgery, aorto-Ieft ventricular tunnel was found and repaired successfully. Review of echocardiogram and catheterization data revealed interesting findings to differentiate this rare entity from congenital...
متن کاملبررسی اثر کاهش حجم بر روی پارامترهای دیاستولیک اکو کاردیوگرافی در بیماران همودیالیزی
Background: Cardiovascular problems including arterial hypertension, coronary artery diseases, congestive heart failure are prevalent among chronic hemodialyzed patients. Ultrafiltration of hemodialyzed patient's serum, which culminating in intravascular volume reduction, is frequently used during hemodialysis. One of the restrictions of the echocardiographic evaluation of the diastolic heart f...
متن کاملبررسی یافته های اکوکاردیو گرافیک قلبی در بیماران سیروز کبدی
Introduction: Cardiovascular abnormalities have been reported in liver cirrhosis (LC). In these patients, cardiac symptoms and physical signs occur as the liver functions worsen. Cirrhosis is associated with hyper dynamic circulation and beta-adrenergic system changes responsible for the cardiovascular abnormalities. The purpose of the present study was to explore the echocardiographic findi...
متن کاملDimensions and volumes of left atrium and ventricle determined by single beam echocardiography.
This study further extends the clinical usefulness of the estimation of cardiac chamber size by means of single echocardiographic dimensions. In 24 patients left atrial size was calculatedfrom an anteroposterior standard echographic dimension and correlates (r=o088) with the left atrial surface area measured from selective cineangiograms in the right anterior oblique position. For clinical use ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British heart journal
دوره 38 11 شماره
صفحات -
تاریخ انتشار 1976