Short-Circuit Withstand Tests of 2605SA1-based Amorphous Distribution Transformers
نویسندگان
چکیده
This paper deals with EDF Research and Development work for ERDF needs in terms of energy efficiency, focused on Amorphous Metal Distribution Transformers (AMDT). Many prototypes built on METGLAS® 2605SA1, rated 250 to 630 kVA from different manufacturers, were tested under short-circuit conditions according to IEC and ERDF standards. Some of the prototypes exceeded the accepted value of 4% of impedance variation after short-circuit. Rectangular windings offer poor resistance to short-circuit stresses. Small metal particles, detached from amorphous core, were found at the bottom of the tank. In that case, dielectric strength is not gifted. The results show the active part should be strong enough to support high electrodynamic forces produced during short-circuit test.
منابع مشابه
Physicochemical and Aging Tests of 2605SA1 and 2605HB1 Amorphous Ribbons for Power Applications
To evaluate the physicochemical compatibility of rapidly solidified ribbons with transformer insulating fluids, isothermal heating process was carried out in order to prove the sustainability of these materials. Fe-based amorphous ribbons were immersed in mineral and vegetable transformer oils for a period of 580 hours at 110 and 140°C. Chemical analyses of oils after experimentation have shown...
متن کاملA Fast Method for Calculation of Transformers Leakage Reactance Using Energy Technique
Energy technique procedure for computing the leakage reactance in transformers is presented. This method is very efficient compared with the use of flux element and image technique and is also remarkably accurate. Examples of calculated leakage inductances and the short circuit impedance are given for illustration. For validation, the results are compared with the results obtained using practic...
متن کاملArtificial Intelligence Based Approach for Identification of Current Transformer Saturation from Faults in Power Transformers
Protection systems have vital role in network reliability in short circuit mode and proper operating for relays. Current transformer often in transient and saturation under short circuit mode causes mal-operation of relays which will have undesirable effects. Therefore, proper and quick identification of Current transformer saturation is so important. In this paper, an Artificial Neural Network...
متن کاملNew Design of Traction Transformers for Fixed Installations
In this paper an analysis of different designs of traction transformers is given. The paper describes three-limb transformer design for 7.5 MVA and 10 MVA units and two-limb transformer design for 15 MVA and 16 MVA units. Paper also represents noise level measurement results and sound intensity frequency spectrum for 16 MVA unit. Based on results of measurements taken during heat run test on tr...
متن کاملمدلسازی عددی و تحلیل نیروهای الکترومغناطیسی ترانسفورماتور اُوال و مقایسه آن با ترانسفورماتور سیلندری با استفاده از روش اجزای المان محدود
Distribution transformers with OVAL windings introduces as optimal Optimums transformers in the lowest power. Because consumption of Iron and copper decrease in these transformers, it decreases Loss of power transformers than cylindertransformers. Pay attention to the level of deformation transformers in OVAL, its electromagnetic forces will be reduced. All Articles have given different methods...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -