Simulations of a FIR Oscillator with Large Slippage parameter at Jefferson Lab for FIR/UV pump-probe experiments

نویسندگان

  • S V Benson
  • L T Campbell
  • B W J McNeil
  • G R Neil
  • M D Shinn
  • G P Williams
چکیده

We previously proposed a dual FEL configuration on the UV Demo FEL at Jefferson Lab that would allow simultaneous lasing at FIR and UV wavelengths [1]. The FIR source would be an FEL oscillator with a short wiggler providing diffraction-limited pulses with pulse energy exceeding 50 microJoules, using the exhaust beam from a UVFEL as the input electron beam. Since the UV FEL requires very short pulses, the input to the FIR FEL is extremely short compared to a slippage length and the usual Slowly Varying Envelope Approximation (SVEA) does not apply. We use a non-SVEA code [2] to simulate this system both with a small energy spread (UV laser off) and with large energy spread (UV laser on).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ASTRONOMY AND ASTROPHYSICS Far infrared and Ultraviolet emissions of individual galaxies at z=0: selection effects on the estimate of the dust extinction

We have cross-correlated Far Infrared (IRAS) and UV (FOCA) observations of galaxies to construct a sample of FIR selected galaxies with a UV observation at 0.2 μm. The FIR and UV properties of this sample are compared to the mean properties of the local Universe deduced from the luminosity distributions at both wavelengths. Almost all the galaxies of our sample have a FIR to UV flux ratio large...

متن کامل

Far infrared and Ultraviolet emissions of individual galaxies at z=0: selection effects on the estimate of the dust extinction

We have cross-correlated Far Infrared (IRAS) and UV (FOCA) observations of galaxies to construct a sample of FIR selected galaxies with a UV observation at 0.2 μm. The FIR and UV properties of this sample are compared to the mean properties of the local Universe deduced from the luminosity distributions at both wavelengths. Almost all the galaxies of our sample have a FIR to UV flux ratio large...

متن کامل

A Dsp-based Beam Current Monitoring System for Machine Protection Using Adaptive Filtering

The CEBAF accelerator at Jefferson Lab is currently using an analog beam current monitoring (BCM) system for its machine protection system (MPS), which has a loss accuracy of 2 μA. Recent burn-through simulations predict catastrophic beam line component failures below 1 μA of loss, resulting in a blind spot for the MPS. Revised MPS requirements target an ultimate beam loss accuracy of 250 nA. A...

متن کامل

Stabilized, Integrated, Far-Infrared Laser System for NASA/Goddard Space Flight Center

DeMaria ElectroOptics Systems (DEOS) has delivered a highly-integrated, turnkey, Far-Infrared laser system to NASA/Goddard Space Flight Center, as a precursor for a system for SOFIA. This system has a number of unique features including: a permanently sealed-off 100W-class pump laser, an absolute heterodyne frequency lock for the pump laser, a folded extended-service sealed-off FIR laser, all e...

متن کامل

Program and Book of Abstracts

A double-path radially viewing multichannel far-infrared (FIR) polarimeter/interferometer system is under development for current density profile and electron density profile measurements for EAST tokamak. The system utilizes three 432 m CW formic acid FIR lasers pumped by three CO2 lasers. Three FIR lasers can generate high output power, more than 30 mW at each cavity. Two of them will be coun...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013