Mechanical thrombolysis: a new rotational catheter approach for acute thrombi.

نویسندگان

  • J L Ritchie
  • D D Hansen
  • R Vracko
  • D C Auth
چکیده

We tested a new rotational thrombectomy catheter in acute thrombi formed both in vitro and in vivo. The catheter consisted of a rounded platinum tip, 0.025 inch diameter by 0.08 inch long, attached to a flexible steel guidewire supported by an external sheath. In vitro, the force required to penetrate thrombus was reduced fivefold by rotation of the catheter at 4000 rpm (0.75 +/- 1.2 g rotating vs 3.9 +/- 2.1 g static; p less than .001). Fibrin was extracted selectively from the thrombus and tightly wound about the shaft (3.8 +/- 1.5 mg rotating vs 0.75 +/- 0.4 mg static; p less than .001). In vivo, subtotal or complete thrombosis of the canine femoral artery was created. Thrombectomy by catheter rotation always produced tightly wound adherent fibrin on the catheter shaft. Angiographic patency was restored in 20 of 22 (91%) arteries, totally in seven of 22 (32%) and partially (greater than 20% increase in lumen diameter) in 13 of 22 (59%). There was one arterial perforation (5%). We conclude that this new mechanical catheter device reduces the force required to penetrate thrombus. Additionally, by winding fibrin about its shaft, the catheter is able to selectively remove the fibrin matrix of thrombus. Thus both the ease of initial thrombus recanalization as well as physical removal of thrombus are promoted by this new approach. Such an approach may be relevant to the treatment of recent thrombosis in acute myocardial infarction.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

LABORATORY INVESTIGATION THROMBOLYSIS Mechanical thrombolysis: a new rotational catheter approach for acute thrombi

We tested a new rotational thrombectomy catheter in acute thrombi formed both in vitro and in vivo. The catheter consisted of a rounded platinum tip, 0.025 inch diameter by 0.08 inch long, attached to a flexible steel guidewire supported by an external sheath. In vitro, the force required to penetrate thrombus was reduced fivefold by rotation of the catheter at 4000 rpm (0.75 + 1.2 g rotating v...

متن کامل

Successful carotid thrombus aspiration, middle cerebral mechanical thrombectomy, and axillary artery clot disruption attempt in a patient with acute ischemic stroke and critical upper limb ischemia

Acute thrombotic occlusions of the large vessels, such as internal carotid artery, arms and legs arteries, and intracranial vessels, frequently require multiple techniques such as selective thrombolysis, manual aspiration, and stent retrievers for mechanical thrombectomy with combination of the mentioned techniques. Because of the massive thrombotic burden associated with these conditions, the ...

متن کامل

Massive pulmonary embolism: percutaneous emergency treatment by pigtail rotation catheter.

OBJECTIVES This study was designed to assess the feasibility, efficacy and safety of mechanical fragmentation of pulmonary emboli using a new rotational pigtail catheter system. BACKGROUND Acute massive pulmonary embolism associated with right ventricular dysfunction is frequently lethal, despite high-dose thrombolytic therapy. Adjunctive catheter fragmentation may prevent a fatal outcome. ...

متن کامل

Reperfusion therapy of acute ischaemic stroke and acute myocardial infarction: similarities and differences

The evolution of reperfusion therapy in acute myocardial infarction and acute ischaemic stroke has many similarities: thrombolysis is superior to placebo, intra-arterial thrombolysis is not superior to intravenous (i.v.), facilitated intervention is of questionable value, and direct mechanical recanalization without thrombolysis is proven (myocardial infarction) or promising (stroke) to be supe...

متن کامل

Simple mechanical thrombectomy with intrapulmonary arterial thrombolysis in pulmonary thromboembolism: a small case series

Pulmonary thromboembolism (PTE) is a life-threatening condition with a high early mortality rate caused by acute right ventricular failure and cardiogenic shock. We report a series of three patients who presented with acute and subacute submassive PTE. They were successfully treated by simple catheter-based mechanical thrombectomy and intrapulmonary arterial thrombolysis. Mechanical fragmentati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 73 5  شماره 

صفحات  -

تاریخ انتشار 1986