A simple low-SAR technique for chemical-shift selection with high-field spin-echo imaging.
نویسندگان
چکیده
We have discovered a simple and highly robust method for removal of chemical shift artifact in spin-echo MR images, which simultaneously decreases the radiofrequency power deposition (specific absorption rate). The method is demonstrated in spin-echo echo-planar imaging brain images acquired at 7 T, with complete suppression of scalp fat signal. When excitation and refocusing pulses are sufficiently different in duration, and thus also different in the amplitude of their slice-select gradients, a spatial mismatch is produced between the fat slices excited and refocused, with no overlap. Because no additional radiofrequency pulse is used to suppress fat, the specific absorption rate is significantly reduced compared with conventional approaches. This enables greater volume coverage per unit time, well suited for functional and diffusion studies using spin-echo echo-planar imaging. Moreover, the method can be generally applied to any sequence involving slice-selective excitation and at least one slice-selective refocusing pulse at high magnetic field strengths. The method is more efficient than gradient reversal methods and more robust against inhomogeneities of the static (polarizing) field (B(0)).
منابع مشابه
GRASE (gradient- and spin-echo) MR of the brain.
PURPOSE To assess the clinical utility of GRASE (gradient- and spin-echo) MR imaging of the brain by comparing it with the T2-weighted turbo spin-echo technique. METHODS Fifty-three consecutive patients referred for MR imaging of the brain were studied with T2-weighted turbo spin-echo and GRASE techniques, matched for effective echo time (110 milliseconds), echo train length (eight), and spat...
متن کاملHigh-Resolution, Low-SAR T2 Imaging at High Magnetic Fields
The PSIF (gradient-reversed FISP, SSFP, CE-FAST) sequence is demonstrated to produce high-quality, T,-weighted images in human brain at magnetic field strengths of 4 Tesla and above In contrast to spin-echo or multiple-echo imaging techniques commonly used in clinical practice at lower fields, the importance of Bi homogeneity in PSIF imaging is minimal and the average RF power deposition is low...
متن کاملAssessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences
Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of non-homogeneity in RF receive and transmit. This can be the most effective source of error in quantitative studies in MRI imaging. Part of this non-homogeneity demonstrates the characteristics of RF coil and part of it is due to the interaction of RF field with the material being imaged...
متن کاملFast gradient-echo chemical-shift imaging.
A fast chemical-shift imaging using the gradient-echo technique is proposed for the separation of the water and fat in human in vivo imaging. This technique also incorporates magnetic field inhomogeneity correction in the fast chemical-shift imaging. Experimental results of the proposed imaging technique demonstrate that the method would be useful for quick in vivo water-fat separation imaging ...
متن کاملGRASE (gradient- and spin-echo) MR imaging: a new fast clinical imaging technique.
A novel technique of magnetic resonance (MR) imaging, which combines gradient-echo and spin-echo (GRASE) technique, accomplishes T2-weighted multisection imaging in drastically reduced imaging time, currently 24 times faster than spin-echo imaging. The GRASE technique maintains contrast mechanisms, high spatial resolution, and image quality of spin-echo imaging and is compatible with clinical w...