A modified method for fabricating a radiographic stent with transparent occlusal registration material for implant placement.
نویسندگان
چکیده
Figure 1. Apply transparent occlusal registration material. For successful implant placement, the evaluation of anatomic structures is important in deciding the diameter, length, position, and angulation of the implant. Various diagnostic methods such as radiographic stent and cone-beam computed tomography (CBCT) can be used to determine the appropriate position. A radiographic stent can stably position a radiopaque marker without inducing scatter. In addition, it can be comfortably retained in the mouth. Several methods have been introduced for the fabrication of a radiographic stent, including duplicating the existing restoration with clear resin and using silicone putty or a vacuum-formed matrix on the diagnostic cast. However, these methods require an additional impression or laboratory procedures. This article describes a straightforward method of fabricating a radiographic stent with a transparent occlusal registration material at the chairside. It does not require an impression or laboratory procedures. Because a transparent material is used, the location of the radiopaque marker can be confirmed visually. In addition, the position and the angle of the implant can be planned by considering the occlusal relation because the occlusal surface is recorded simultaneously. Because this method is not based on transferring information from a diagnostic waxing, it cannot be appropriate for an edentulous space or a more extensive posterior edentulous area. However, it is effective for evaluating the quantity and the shape of alveolar bone
منابع مشابه
ساخت استنت رادیوگرافی و جراحی برای ایمپلنت های ماگزیلوفیشیال
A procedure was explained to fabricate a surgical stent to aid the placement of maxillofacial implants for prosthetic auricular rehabilitation. An impression of the defect was made, and a wax pattern of the missing ear completed and evaluated on the patient. The definitive wax prosthesis was processed in clear acrylic resin. Also an occlusal maxillary splint was fabricated and joined to the acr...
متن کاملRadiographic Comparison of Crestal Bone Loss Around Two Implant Systems with Different Surface Roughness: A Retrospective Study
Background and Aim: This retrospective study aimed to investigate the effects of surface roughness and implant body design on the amount of crestal bone loss around implant. Materials and Methods: In this retrospective study, dental records of 87 patients who received 139 implants were evaluated. The ITI group received 63 implants with moderate roughness, while the DIO group received 76 implan...
متن کاملIn-vitro study on the accuracy of a simple-design CT-guided stent for dental implants
PURPOSE An individual surgical stent fabricated from computed tomography (CT) data, called a CT-guided stent, would be useful for accurate installation of implants. The purpose of the present study was to introduce a newly developed CT-guided stent with a simple design and evaluate the accuracy of the stent placement. MATERIALS AND METHODS A resin template was fabricated from a hog mandible a...
متن کاملA technique for making impressions of deeply placed implants.
aAssistant Professor, Division of Prosthodontics, Institute of Odontology, Faculty of Medicine, Vilnius University. bResident, Division of Prosthodontics, Institute of Odontology, Faculty of Medicine, Vilnius University. cPrivate practice, Vilnius, Lithuania. dLecturer, Division of Orthodontics, Institute of Odontology, Faculty of Medicine, Vilnius University. (J Prosthet Dent 2011;106:204-205)...
متن کاملFabricating radiographic stents in implant treatment planning.
This article provides a step-by-step procedure for producing radiographic stents. Two common treatment scenarios are explored.