Live/real time three-dimensional transesophageal echocardiographic evaluation of mitral and aortic valve prosthetic paravalvular regurgitation.

نویسندگان

  • Preeti Singh
  • Jayaprakash Manda
  • Ming Chon Hsiung
  • Anjlee Mehta
  • Saritha Kumari Kesanolla
  • Navin C Nanda
  • Shen-Kou Tsai
  • Jeng Wei
  • Wei-Hsian Yin
چکیده

Thirteen patients already scheduled for surgery for repair of prosthetic paravalvular regurgitation underwent intraoperative real time two-dimensional transesophageal echocardiography (2D TEE) and live/real time three-dimensional transesophageal echocardiography (3D TEE). In all patients, 3D TEE was able to provide more information regarding the location and size of the paravalvular defect as compared to 2D TEE. 3D TEE resulted in a more accurate localization of the defect and an estimation of the size of the defect that correlated much more closely with surgical findings when compared with 2D TEE. Our preliminary results demonstrate the superiority of 3D TEE over 2D TEE in the evaluation of paravalvular prosthetic regurgitation. 3D TEE not only provides an accurate assessment of the exact site of the leakage, but also gives a more accurate estimate of its size. This information could be valuable to surgeons who may encounter difficulty when localizing and estimating the size of paraprosthetic leaks while the heart is devoid of blood during surgery.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Björk-Shiley prosthetic valves by real-time two-dimensional Doppler echocardiographic flow mapping.

We studied the value of two-dimensional Doppler echocardiographic color flow mapping for identifying normal transvalve flow profiles and valve malfunction in 20 patients with Björk-Shiley prosthetic valves. Seven patients had Björk-Shiley prosthetic valves in the aortic position alone, seven in the mitral position, and six had prosthetic valves in both the aortic and mitral positions. In 10 pat...

متن کامل

Three-dimensional transesophageal echocardiogram provides real-time guidance during percutaneous paravalvular mitral repair.

A 65-year-old woman with severe paravalvular mitral regurgitation and chronic hemolytic anemia was referred for surgical consultation. Her medical history included rheumatic heart disease with mitral valve replacement in 1977, aortic valve replacement in 1988, and repeat mechanical mitral valve replacement in 2002. Predominant symptoms were New York Heart Association function class III dyspnea ...

متن کامل

Accuracy of 3-Dimensional Transoesophageal Echocardiography in Assessment of Prosthetic Mitral Valve Dehiscence with Comparison to Anatomical Specimens

The evolution of echocardiography from 2-Dimensional Transthoracic Echo through to real time 3-Dimensional Transoesophageal Echo has enabled more accurate visualisation and quantification of valvular disorders especially prosthetic mitral valve paravalvular regurgitation. However, validation of accuracy is rarely confirmed by surgical or post-mortem specimens. We present a case directly compari...

متن کامل

Bioptome injury to the tricuspid valve in a cardiac allograft recipient visualized by three-dimensional echocardiography.

1999;88:1205–12. 7. Troianos CA, Konstadt S. Evaluation of mitral regurgitation. Semin Cardiothorac Vasc Anesth 2006;10:67–71. 8. Cook RC, Nifong LW, Lashley GG, Duncan RA, Campbell JA, Law YB et al. Echocardiographic measurements alone do not provide accurate non-invasive selection of annuloplasty band size for robotic mitral valve repair. J Heart Valve Dis 2006;15:524–7. 9. Ender J, Koncar-Ze...

متن کامل

Diagnosis of prosthetic mitral valve malfunction with combined echo-phonocardiography.

Fifty-three patients were studied with combined echo-phonocardiography or phonocardiography alone following prosthetic valve replacement. In sixteen of these patients, clinical deterioration developed, and all subsequently underwent cardiac catheterization and/or surgery. Two patients came to autopsy. Included in this group of sixteen patients were five with obstructed prosthesis, six with para...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Echocardiography

دوره 26 8  شماره 

صفحات  -

تاریخ انتشار 2009