Indirect Ultrasound Guidance Increased Accuracy of the Glenohumeral Injection Using the Superior Approach: A Cadaveric Study of Injection Accuracy

نویسندگان

  • Joon Sung Kim
  • Min-Wook Kim
  • Dong Yoon Park
چکیده

OBJECTIVE To investigate whether or not indirect ultrasound guidance could increase the accuracy of the glenohumeral joint injection using the superior approach. METHODS Twelve shoulders from 7 adult cadavers were anatomically dissected after a dye injection had been performed, while the cadavers were in the supine position. Before the injection, a clinician determined the injection point using the ultrasound and the more internal axial arm rotation was compared to how it was positioned in a previous study. Injection confidence scores and injection accuracy scores were rated. RESULTS The clinician's confidence score was high in 92% (11 of 12 shoulders) and the injection accuracy scores were 100% (12 of 12 shoulders). The long heads of the biceps tendons were not penetrated. CONCLUSION Indirect ultrasound guidance and positioning shoulder adducted at 10° and internally rotated at 60°-70° during the superior glenohumeral joint injection would be an effective method to avoid damage to the long head of biceps tendons and to produce a highly accurate injection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of ultrasound-guided versus blind glenohumeral injections: a cadaveric study.

BACKGROUND Intra-articular glenohumeral (GH) injections are important for diagnostic and therapeutic purposes. It has been suggested that ultrasound guided injections are more accurate than blind or freehand injections. This study assessed the accuracy of ultrasound-guided GH injections compared with freehand injections in fresh cadavers. METHODS The study used 80 shoulder specimens from fres...

متن کامل

Improving injection accuracy of the elbow, knee, and shoulder: does injection site and imaging make a difference? A systematic review.

BACKGROUND Joint injections and aspirations are used to reduce joint pain and decrease inflammation. The efficacy of these injections is diminished when they are placed inadvertently in the wrong location or compartment. The purpose of this study was to determine whether the use of varying sites or imaging techniques affects the rate of accurate needle placement in aspiration and injection in t...

متن کامل

Ultrasound Measurements of the ECRB Tendon Shows Remarkable Variations in Patients with Lateral Epicondylitis

Background: Lateral epicondylitis (LE) most commonly affects the Extensor Carpi Radialis Brevis (ECRB) tendon andpatients are generally treated with injection therapy. For optimal positioning of the injection, as well as an estimation ofthe surface area and content of the ECRB tendon to determine the volume of the injectable needed, it is important toknow the exact location of...

متن کامل

Ultrasound guidance for intra-articular knee and shoulder injections: a review.

Intra-articular injections have traditionally been performed "blind," guided only by anatomic palpation. Many may be placed inaccurately, and the use of imaging may significantly improve injection accuracy. This review analyzed the impact of ultrasound-guidance on injection accuracy and clinical efficacy in the knee and shoulder joints. Ultrasound-guided injections were significantly more accur...

متن کامل

The effect of injection parameters on dimensional accuracy of wax patterns for investment casting

Thermal expansion and hot deformation are two phenomena causing dimensional errors in investment casting. This error occurs in dimensions between the die and wax pattern. Therefore, the wax's thermo-physical and thermo-mechanical properties, the metal die features, and the process parameters affect the dimensions of the wax pattern. Some important effective process parameters are the injection ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 37  شماره 

صفحات  -

تاریخ انتشار 2013