A validation study of the use of near-infrared spectroscopy imaging in primary and secondary motor areas of the human brain
نویسندگان
چکیده
The electroencephalographically measured Bereitschafts (readiness)-potential in the supplementary motor area (SMA) serves as a signature of the preparation of motor activity. Using a multichannel, noninvasive near-infrared spectroscopy (NIRS) imager, we studied the vascular correlate of the readiness potential. Sixteen healthy subjects performed a self-paced or externally triggered motor task in a single or repetitive pattern, while NIRS simultaneously recorded the task-related responses of deoxygenated hemoglobin (HbR) in the primary motor area (M1) and the SMA. Right-hand movements in the repetitive sequence trial elicited a significantly greater HbR response in both the SMA and the left M1 compared to left-hand movements. During the single sequence condition, the HbR response in the SMA, but not in the M1, was significantly greater for self-paced than for externally cued movements. Nonetheless, an unequivocal temporal delay was not found between the SMA and M1. Near-infrared spectroscopy is a promising, noninvasive bedside tool for the neuromonitoring of epileptic seizures or cortical spreading depolarizations (CSDs) in patients with epilepsy, stroke, or brain trauma because these pathological events are associated with typical spatial and temporal changes in HbR. Propagation is a characteristic feature of these events which importantly supports their identification and characterization in invasive recordings. Unfortunately, the present noninvasive study failed to show a temporal delay during self-paced movements between the SMA and M1 as a vascular correlate of the readiness potential. Although this result does not exclude, in principle, the possibility that scalp-NIRS can detect a temporal delay between different regions during epileptic seizures or CSDs, it strongly suggests that further technological development of NIRS should focus on both improved spatial and temporal resolution. This article is part of a Special Issue entitled Status Epilepticus.
منابع مشابه
Optical Imaging of the Motor Cortex in the Brain in Order to Determine the Direction of the Hand Movements Using Functional Near-Infrared Spectroscopy (fNIRS)
Introduction: In recent years, optical imaging has attracted a lot of attention from scholars as a non- aggressive, efficient method for evaluating the activities of the motor cortex in the brain. Functional near-infrared spectroscopy (fNIRS (is a tool showing the hemodynamic changes in a cortical area of the brain according to optical principles. The present study has been de...
متن کاملQuantitative Comparison of Analytical solution and Finite Element Method for investigation of Near-Infrared Light Propagation in Brain Tissue Model
Introduction: Functional Near-Infrared Spectroscopy (fNIRS) is an imaging method in which light source and detector are installed on the head; consequently, re-emission of light from human skin contains information about cerebral hemodynamic alteration. The spatial probability distribution profile of photons penetrating tissue at a source spot, scattering into the tissue, and being released at ...
متن کاملDevelopment of near infrared reflectance spectroscopy (NIRS) calibration model for estimation of oil content in a worldwide safflower germplasm collection
The development of NIRS calibration model as a rapid, precise, robust, and cost-effective method to estimate oil content in ground seeds of worldwide safflower germplasm collection grown under different agro-climatic conditions was the key objective of this research project. The oil content was measured by accelerated solvent extraction method in a total of 328 samples collected across 2004 (16...
متن کاملModeling Time Resolved Light Propagation Inside a Realistic Human Head Model
Background: Near infrared spectroscopy imaging is one of the new techniques used for investigating structural and functionality of different body tissues. This is done by injecting light into the medium and measuring the photon intensity at the surface of the tissue.Method: In this paper the different medical applications, various imaging and simulation techniques of NIRS imaging is described. ...
متن کاملImproving 3-D Imaging Breast Cancer Diagnosis Systems Using a New Method for Placement of Near-Infrared Sources and Detectors
The objective of this research was to improve 3-D imaging system by near-infrared light emission in breast tissue to achieve a more accurate diagnosis of tumor. The results of repeated experiments in this research have shown that with this imaging system, a more accurate diagnosis of abnormal area depends on the location of the sources and detectors. Therefore, an optimal location model has bee...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Epilepsy & Behavior
دوره 49 شماره
صفحات -
تاریخ انتشار 2015