Pulse Oximetry Wave Variation as a Noninvasive Tool to Assess Volume Status in Cardiac Surgery

نویسندگان

  • Glauco A Westphal
  • Eliezer Silva
  • Anderson Roman Gonçalves
  • Milton Caldeira Filho
  • Luíz F Poli-de-Figueiredo
چکیده

OBJECTIVE To compare variations of plethysmographic wave amplitude (DeltaPpleth) and to determine the percent difference between inspiratory and expiratory pulse pressure (DeltaPp) cutoff values for volume responsiveness in a homogenous population of postoperative cardiac surgery patients. INTRODUCTION Intra-thoracic pressure variations interfere with stroke volume variation. Pulse pressure variations through arterial lines during mechanical ventilation have been recommended for the estimation of fluid responsiveness. Pulse oximetry may offer a non-invasive plethysmographic method to evaluate pulse pressure; this may be useful for guiding fluid replacement. METHODS Controlled, prospective study in cardiac surgery patients under controlled ventilation. Simultaneous digital recordings of arterial pressure and plethysmographic waves were performed. DeltaPp, systolic pressure (DeltaPs), DPpleth, and systolic component (DeltaSpleth) were calculated. A DPp > or = 13% identified fluid-responsive patients. Volume expansion was performed in responsive subjects. Systolic and amplitude components of pressure and plethysmographic waves were compared. RESULTS In 50 measurements from 43 patients, DeltaPp was correlated with (Ppleth (r=0.90, p<0.001), (Ps (r=0.90, p<0.001), and (Spleth (r=0.73, p<0.001). An aArea under ROC curve (AUC) identified the fluid responsiveness thresholds: (Ppleth of 11% (AUC = 0.95+/-0.04), (Ps of 8% (AUC=0.93+/-0.05), and (Spleth of 32% (AUC=0.82+/-0.07). A (Ppleth value > or = 11% predicted (Pp > or = 13% with 100% specificity and 91% sensitivity. Volume expansion, performed in 20 patients, changed (Pp, (Ppleth, (Ps and (Spleth significantly (p<0.008). CONCLUSIONS DeltaPpleth is well correlated with DPp and constitutes a simple and non-invasive method for assessing fluid responsiveness in patients following cardiac surgery.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pleth variability index and fluid responsiveness of hemodynamically stable patients after cardiothoracic surgery.

BACKGROUND Fluid responsiveness is a measure of preload dependence and is defined as an increase in cardiac output due to volume expansion. Recent publications have suggested that variation in amplitude of the pulse oximetry waveform may be predictive of fluid responsiveness. The pleth variability index (PVI) was developed as a noninvasive bedside measurement of this variation in the pulse oxim...

متن کامل

Normal Echocardiographic Findings in Healthy Pigeons

Objective- The purpose of this study was to investigate the feasibility of performing echocardiography in apparently healthy pigeons, and measurement of the quantitative cardiac indices using B-mode and Doppler techniques. Design- Experimental study Animals- Ten apparently healthy pigeons Procedures- Echocardi...

متن کامل

Pulse oximeter as a sensor of fluid responsiveness: do we have our finger on the best solution?

The pulse oximetry plethysmographic signal resembles the peripheral arterial pressure waveform, and the degree of respiratory variation in the pulse oximetry wave is close to the degree of respiratory arterial pulse pressure variation. Thus, it is tempting to speculate that pulse oximetry can be used to assess preload responsiveness in mechanically ventilated patients. In this commentary we bri...

متن کامل

Detecting change in left ventricular ejection time during head-up tilt-induced progressive central hypovolemia using a finger photoplethysmographic pulse oximetry wave form.

BACKGROUND Change in cardiac preload caused by mild hypovolemia can alter left ventricular ejection time (LVET) without noticeable change in blood pressure (BP). Previously our group has explored a novel method of LVET monitoring using a noninvasive finger photoplethysmographic pulse oximetry wave form. The current study investigated the ability of photoplethysmographic pulse oximetry wave form...

متن کامل

Respiratory Variation in Pulse Oximetry: A Simple Fluid Responsiveness Parameter

Respiratory variation in arterial pulse pressure (ΔPP) has been shown to be the most accurate predictor of fluid responsiveness in mechanically ventilated patients, with a predictive cutoff value of 13%. However, this dynamic parameter is invasive and not widely available. The pulse oximetry plethysmographic (POP) signal resembles the arterial pressure waveform in both shape and amplitude varia...