Effects of porosity on the fatigue performance of polymethyl methacrylate bone cement: an analytical investigation.

نویسنده

  • S L Evans
چکیده

Porosity has been shown to affect the fatigue life of bone cements, but, although vacuum mixing is widely used to reduce porosity in the clinical setting, results have been mixed and the effects of porosity are not well understood. The aim of this study was to investigate the effects of porosity using stress analysis and fracture mechanics techniques. The stress concentrations arising at voids in test specimens were found using analytical solutions and boundary element methods. The fatigue life of specimens containing voids of various sizes was predicted using fracture mechanics techniques. For spherical voids that do not occupy a significant proportion of the cross-section, the resulting stress concentration is independent of void size and too small to account for the observed crack initiation. Cracks must therefore initiate at additional stress raisers such as radiopacifier particles or additional voids. For large voids, the stress increases as the remaining cross-section of the specimen decreases, and this may account for much of the observed reduction in fatigue strength in hand-mixed cement. Although crack initiation may be largely independent of void size, there is an effect on crack growth rate. Cracks are predicted to grow faster around larger voids, since they remain in the stress concentration around the void for longer. This effect may account for the relationship between porosity and fatigue life that has been observed in samples without large voids. Since porosity appears to affect crack growth more than initiation, it may be less damaging in high-cycle clinical fatigue, which may be predominantly initiation controlled, than in short laboratory tests.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bone cement pdf

The genesis and evolution of acrylic bone cement. Otto Röhm is known as the developer of polymethylmethacrylate PMMA in 1901. Preparation and Characterization of Injectable Brushite. Filled-Poly Methyl Methacrylate Bone Cement. Rodriguez 1, Jonathan Chari.Bone cement implantation syndrome. 1Department of Anaesthesia, University Hospital of. Problems with modern bone cements such as the loosenin...

متن کامل

Nanoindentation of microstructural elements in bone cement

Introduction: Poly(methyl methacrylate), or PMMA bone cement has been a critical material in total joint replacement for over four decades. Modifications used to improve the standard polymer powder/methacrylate monomer system have included the addition of fiber reinforcing phases, bioactive ceramics, antibiotic agents, etc. The microstructural phases in PMMA bone cement can affect its fracture ...

متن کامل

Fixation of the Cemented Stem: Clinical Relevance of the Porosity and Thickness of the Cement Mantle

The aim of this review paper is to define the fixation of the cemented stem. Polymethyl methacrylate, otherwise known as "bone cement", has been used in the fixation of hip implants since the early 1960s. Sir John Charnley, the pioneer of modern hip replacement, incorporated the use of cement in the development of low frictional torque hip arthroplasty. In this paper, the concepts of femoral st...

متن کامل

The long-term in vivo behavior of polymethyl methacrylate bone cement in total hip arthroplasty

BACKGROUND AND PURPOSE The long-term success of cemented total hip arthroplasty (THA) has been well established. Improved outcomes, both radiographically and clinically, have resulted mainly from advances in stem design and improvements in operating techniques. However, there is concern about the durability of bone cement in vivo. We evaluated the physical and chemical properties of CMW1 bone c...

متن کامل

Ageing and moisture uptake in polymethyl methacrylate (PMMA) bone cements☆

Bone cements are extensively employed in orthopaedics for joint arthroplasty, however implant failure in the form of aseptic loosening is known to occur after long-term use. The exact mechanism causing this is not well understood, however it is thought to arise from a combination of fatigue and chemical degradation resulting from the hostile in vivo environment. In this study, two commercial bo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine

دوره 220 1  شماره 

صفحات  -

تاریخ انتشار 2006