In this report, we present 34 patients in whom surgical intervention was undertaken for severe mitral insufficiency due to mitral valve prolapse (MVP). Location and severity of MVP and regurgitation were assessed preoperatively by live/real time three-dimensional transthoracic echocardiography and closely agreed with the surgical findings.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of real time two-dimensional with live/real time three-dimensional transesophageal echocardiography in the evaluation of mitral valve prolapse and chordae rupture.

We compared live/real time three-dimensional transesophageal echocardiography (3D TEE) with real time two-dimensional transesophageal echocardiography (2D TEE) in the assessment of individual mitral valve (MV) segment/scallop prolapse and associated chordae rupture in 18 adult patients with a flail MV undergoing surgery for mitral regurgitation. 2D TEE was able to diagnose the prolapsing segmen...

متن کامل

Effect of position on echocardiographic diagnosis of mitral valve prolapse

Echocardiography has been accepted as the diagnostic modality of choice for mitral valve prolapse (MVP). The determine the effect of position on echocardiographic diagnosis of MVP, we examined 693 consecutive patients referred to the echocardiography laboratory because of suspected MVP. First, patients were examined using the usual standard M-Mode echocardiography( left parasternal third or fou...

متن کامل

Utility of real‐time three‐dimensional echocardiography in improved assessment of a mitral valve papillary fibroelastoma

Primary cardiac tumors are exceedingly rare. They are usually first identified by transthoracic echocardiography. However, transesophageal echocardiography (TEE), with the aid of real-time three-dimensional (3D) imaging, can provide additional important mass characteristics. We present a case that demonstrates the usefulness of 3D TEE in characterizing a papillary fibroelastoma.

متن کامل

in the Evaluation of Mitral Valve Prolapse

we studied 49 consecutive patients in whom the sites of mitral valve prolapse were confirmed at the time of operation. The study group consisted of 22 patients with anterior leaflet prolapse, 24 patients with posterior leaflet prolapse, and three patients with multiple scallop prolapse (one patient with both anterior leaflet and middle scallop prolapse, and two patients with both medial and lat...

متن کامل

Head-to-head comparison of two- and three-dimensional transthoracic and transesophageal echocardiography in the localization of mitral valve prolapse.

OBJECTIVES The aim of this study, undertaken in patients who underwent mitral valve (MV) repair surgery, was to evaluate the feasibility and accuracy of 3-dimensional (3D) transthoracic (TTE) and transesophageal (TEE) echocardiography in the evaluation of MV pathology. BACKGROUND A pre-operative assessment of MV anatomy is essential to surgical design in patients undergoing MV repair. Althoug...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Echocardiography

دوره 23 6  شماره 

صفحات  -

تاریخ انتشار 2006