Transpedical Interbody Bone Grafting in the Treatment of Senile Osteoporotic Vertebral Fracture

نویسندگان

  • Zhiwei Qin
  • Hong Liu
  • Guiying Chen
  • Guifeng Liu
  • Peng Zhang
  • Haitao Zhu
چکیده

Objective To evaluate the clinical effect of transpedical interbody bone grafting in the treatment of senile osteoporotic vertebral fracture. Methods Eighty-six elders with osteoporotic vertebral fracture were selected and divided into a control group and a test group using random double-blind method. Patients in the control group were treated by short-segment transpedicular screw system internal fixation, while patients in the test group were treated by short-segment transpedicular screw system internal fixation in combination with transpedical interbody bone grafting. Operation related indexes and fracture recovery condition were compared between the two groups. Results The overall effective rate of the test group was 93.02%, much higher than the control group (76.74%) (P<0.05). The difference of operation duration, intraoperative bleeding volume, length of hospital stay, fracture healing time, preoperative vertebral height loss and preoperative Cobb's angle between the two groups had no statistical significance (P>0.05). The postoperative pain score of the test group was lower than that of the control group, and the difference was statistically significant (P<0.05). The vertebral height loss and Cobb's angle of the test group were superior to those of the control group at the last follow up, and the difference had statistical significance (P<0.05). The incidence of internal fixator loosening of the test group was much lower than that of the control group (P<0.05). Conclusion Short-segment transpedicular screw system internal fixation in combination with transpedical interbody bone grafting shows favorable effects in the treatment senile osteoporotic vertebral fracture, resulting in mild pain and less loss of vertebral height and angle; hence it is worth promotion in clinic.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Percutaneous Vertebroplasty in Iranian Patients with Osteoporotic Vertebral Fractures

Background: Osteoporotic compression vertebral fractures are common clinical problems. In those with refractory fractures, percutaneous cement augmentation has been suggested. The aim of this study was to evaluate the functional outcome of percutaneous vertebroplasty in Iranian patients with refractory osteoporotic fractures. Methods: We retrospectively studied 37 osteoporotic fractures in 28 p...

متن کامل

Revision Fixation of Distal Humerus Fracture Nonunions in Older Age Patients with Poor Bone Quality or Bone Loss – Is This Viable as a Long-term Treatment Option?

Background: The purpose of this retrospective study was to analyze the long-term results of revision ORIF, jointcontracture release, and autogenous bone-grafting in the treatment of distal humerus frac-ture nonunions in older agedpatients with poor bone quality or bone loss who would have been candidates for total elbow arthroplasty.Methods: Seven patients (average age at inde...

متن کامل

Circumferential thoracolumbar corrective fusion with an anterior interbody fresh-frozen femoral head allograft for osteoporotic lower acute kyphosis: a case report

INTRODUCTION Lower acute kyphosis (LAK) is a postural deformity caused by severe osteoporotic vertebral collapse at the thoracolumbar junction. Corrective surgery is indicated for severe cases, but no case report using a fresh-frozen femoral head allograft was found in the English literature. CASE PRESENTATION A 69-year-old Japanese woman with severe LAK with osteoporotic vertebral fractures ...

متن کامل

Osteosynthesis without instrumentation for vertebral pseudarthrosis in the osteoporotic spine.

We have performed simple bone grafting in four elderly patients with pain due to unstable pseudarthroses in the osteoporotic spine after compression fracture. At operation, we observed abnormal movement of the affected vertebral body which was covered with a hypertrophic membrane; this seemed to inhibit the blood supply to the lesion. The thick membrane and avascular granulation in the false jo...

متن کامل

Vertebral body fracture after anterolateral instrumentation and interbody fusion in two osteoporotic patients.

BACKGROUND CONTEXT The XLP plate is an anterolateral instrumentation system developed as a part of the eXtreme Lateral Interbody Fusion (XLIF) system for lateral transpsoas interbody fusion, an alternative to anterior interbody fusion. PURPOSE To report two cases of atraumatic coronal plane vertebral body fractures in the early postoperative period after interbody fusion using XLIF cages, lat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 33  شماره 

صفحات  -

تاریخ انتشار 2017