Pedicle screw placement with O-arm and stealth navigation.
نویسندگان
چکیده
Various navigation systems are available to aid pedicle screw placement. The O-arm replaces the need for fluoroscopy and generates a 3-dimensional volumetric dataset that can be viewed as transverse, coronal, and sagittal images of the spine, similar to computed tomography (CT) scanning. The dataset can be downloaded to the Stealth system (Medtronic Navigation, Louisville, Colorado) for real-time intraoperative navigation.The main objectives of the current study were to assess (1) accuracy of pedicle screw placement using the O-arm/Stealth system, and (2) time for draping, positioning of the O-arm, and screw placement. Of 188 screws (25 patients), 116 had adequate images for analysis. The average time for O-arm draping was 3.5 minutes. Initial O-arm positioning was 6.1 minutes, and final positioning was 4.9 minutes. Mean time for screw placement, including O-arm draping and positioning and array attachment, was 8.1 minutes per screw. Mean time for screw placement alone was 5.9 minutes per screw. Screw placements on final O-arm images were on average 3.14 mm deeper than on the snapshot navigation images. Three screws (2.6%) breached the medial cortex, and 3 screws (2.6%) were misaligned and did not follow the pilot hole trajectory.The use of the O-arm/Stealth system was associated with a low rate of pedicle screw misalignment. The time to place screws was less than previously reported with CT navigation, but longer than conventional techniques. It is important to be aware of the potential discrepancy between snapshot navigation images and actual screw placement on final O-arm images. Our findings suggest that final screw positions may be deeper than awl positions appear on navigation images.
منابع مشابه
Analysis of CT-based navigation system for pedicle screw placement.
The incidence of pedicle screw breech varies based on anatomic location, body habitus, surgeon experience, spinal deformity, and surgical technique. Pedicle breeches have been reported to occur in up to 40% of screws. The purpose of this retrospective study was to compare the rates of revision of pedicle screw placement when using intraoperative C-arm vs O-arm (Medtronic, Memphis, Tennessee) as...
متن کاملAccuracy and Safety in Pedicle Screw Placement in the Thoracic and Lumbar Spines : Comparison Study between Conventional C-Arm Fluoroscopy and Navigation Coupled with O-Arm® Guided Methods
OBJECTIVE The authors performed a retrospective study to assess the accuracy and clinical benefits of a navigation coupled with O-arm® system guided method in the thoracic and lumbar spines by comparing with a C-arm fluoroscopy-guided method. METHODS Under the navigation guidance, 106 pedicle screws inserted from T7 to S1 in 24 patients, and using the fluoroscopy guidance, 204 pedicle screws ...
متن کاملAccuracy of Pedicle Screw Placement in Scoliosis Surgery: A Comparison between Conventional Computed Tomography-Based and O-Arm-Based Navigation Techniques
STUDY DESIGN Retrospective study. PURPOSE We compared the accuracy of O-arm-based navigation with computed tomography (CT)-based navigation in scoliotic surgery. OVERVIEW OF LITERATURE No previous reports comparing the results of O-arm-based navigation with conventional CT-based navigation in scoliotic surgery have been published. METHODS A total of 222 pedicle screws were implanted in 29...
متن کاملAccuracy of Intraoperative Computed Tomography–Based Navigation for Placement of Percutaneous Pedicle Screws
MISS techniques have gained recent popularity. The proposed benefits of these techniques include reduced tissue trauma, reduced blood loss, less perioperative pain, and a quicker recovery and return to normal activities. The purpose of this study was to evaluate the accuracy of intraoperative computed tomography (CT)-based navigation for placement of percutaneous pedicle screws in a cadaveric m...
متن کاملUse of a quantitative pedicle screw accuracy system to assess new technology: Initial studies on O-arm navigation and its effect on the learning curve of percutaneous pedicle screw insertion
BACKGROUND A quantitative screw accuracy system is proposed that allows for high-fidelity discrimination between various methods of pedicle screw insertion. Our purpose was to study the utility of a quantitative screw accuracy scoring system to assess new imaging technologies and their effects on the minimally invasive spine learning curve. METHODS By use of a hypothetical "perfect screw," a ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Orthopedics
دوره 35 1 شماره
صفحات -
تاریخ انتشار 2012