Cemented Distal Femoral Endoprostheses for Musculoskeletal Tumor: Improved Survival of Modular versus Custom Implants
نویسندگان
چکیده
BACKGROUND Advocates of newer implant designs cite high rates of aseptic loosening and failure as reasons to abandon traditional cemented endoprosthetic reconstruction of the distal femur. QUESTIONS/PURPOSES We asked whether newer, modular distal femoral components had improved survivorship compared with older, custom-casted designs. PATIENTS AND METHODS We retrospectively reviewed 254 patients who underwent distal femoral endoprosthetic reconstruction. We excluded two patients with cementless implants, 27 with expandable prostheses, and 39 who had a nontumor diagnosis. This left 186 patients: 101 with older custom implants and 85 with contemporary modular implants. The minimum followup was 1 month (mean, 96.0 months; range, 1-336 months). The tumor was classified as Stage IIA/IIB in 122 patients, Stage IA/IB or benign in 43, and Stage III or metastatic in 21. RESULTS Kaplan-Meier analysis revealed overall 10-, 20-, and 25-year implant survival rates of 77%, 58%, and 50%, respectively, using revision of the stemmed components as an end point. The 85 modular components had a greater 15-year survivorship than the 101 custom-designed implants: 93.7% versus 51.7%, respectively. Thirty-five stemmed components (18.8%) were revised for aseptic loosening in 22 patients, implant fatigue fracture in 10, infection in two, and local recurrence in one. CONCLUSIONS Cemented modular rotating-hinge distal femoral endoprostheses demonstrated improved survivorship compared with custom-casted implants during this three-decade experience. Patients with low-grade disease and long-term survivors of high-grade localized disease should expect at least one or more revision procedures in their lifetime. LEVEL OF EVIDENCE Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
منابع مشابه
Cemented Endoprosthetic Reconstruction of the Proximal Tibia: How Long Do They Last?
BACKGROUND The few available studies documenting the long-term survival of cemented proximal tibial endoprostheses for musculoskeletal tumors do not differentiate between stem designs or patient diagnosis. There is wide variation in survival rates reported, possibly a result of this heterogeneity in patient population and implant design. QUESTIONS/PURPOSES We therefore asked: (1) How long do ...
متن کاملHow Long Do Endoprosthetic Reconstructions for Proximal Femoral Tumors Last?
BACKGROUND As the life expectancy of patients with musculoskeletal tumors improves, long-term studies of endoprosthetic reconstructions are necessary to establish realistic expectations for the implants and compare them to other reconstruction approaches. QUESTIONS/PURPOSES (1) What is the long-term survival of cemented bipolar proximal femoral replacements? (2) How does prosthesis survival c...
متن کاملDistal Femoral Replacement for Acute Distal Femoral Fractures in Elderly Patients.
OBJECTIVES To evaluate outcomes and complications using cemented modular distal femoral replacement in elderly patients with distal femoral fractures. DESIGN Retrospective chart review, case series. SETTING A Level 1 and Level 2 trauma center, both tertiary referral hospitals. PATIENTS/PARTICIPANTS Eighteen patients older than 60 years (average age 77 years) who had cemented distal femora...
متن کاملCemented versus cementless endoprostheses for lower limb salvage surgery.
PURPOSE To determine the survival and failures of cemented vs cementless endoprostheses. METHODS We retrospectively studied 232 patients treated with lower limb salvage surgery and reconstruction using cementless and cemented endoprostheses from 2002 to 2007. We compared survival and failures of the endoprostheses regarding age, gender, body mass index (BMI), diagnosis, site of reconstruction...
متن کاملAseptic loosening in cemented custom-made prosthetic replacements for bone tumours of the lower limb.
We have made a retrospective study of 1001 custom-made prostheses used as replacements after surgery for bone tumours. There were 493 distal femoral, 263 proximal femoral and 245 proximal tibial prostheses. Aseptic loosening was shown to be the principal mode of failure of the implants, and 71 patients had revision for aseptic loosening of a cemented intramedullary stem. The probability of a pa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 468 شماره
صفحات -
تاریخ انتشار 2010