Gas molecule scattering & ion mobility measurements for organic macro-ions in He versus N2 environments.

نویسندگان

  • Carlos Larriba-Andaluz
  • Juan Fernández-García
  • Michael A Ewing
  • Christopher J Hogan
  • David E Clemmer
چکیده

A pending issue in linking ion mobility measurements to ion structures is that the collisional cross section (CCS, the measured structural parameter in ion mobility spectrometry) of an ion is strongly dependent upon the manner in which gas molecules effectively impinge on and are reemitted from ion surfaces (when modeling ions as fixed structures). To directly examine the gas molecule impingement and reemission processes and their influence, we measured the CCSs of positively charged ions of room temperature ionic liquids 1-ethyl-3-methylimidazolium dicyanamide (EMIM-N(CN)2) and 1-ethyl-3-methylimidazolium tetrafluoroborate (EMIM-BF4) in N2 using a differential mobility analyzer-mass spectrometer (DMA-MS) and in He using a drift tube mobility spectrometer-mass spectrometer (DT-MS). Cluster ions, generated via electrosprays, took the form (AB)N(A)z, spanning up to z = 20 and with masses greater than 100 kDa. As confirmed by molecular dynamics simulations, at the measurement temperature (∼300 K), such cluster ions took on globular conformations in the gas phase. Based upon their attained charge levels, in neither He nor N2 did the ion-induced dipole potential significantly influence gas molecule-ion collisions. Therefore, differences in the CCSs measured for ions in the two different gases could be primarily attributed to differences in gas molecule behavior upon collision with ions. Overwhelmingly, by comparison of predicted CCSs with selected input impingement-reemission laws to measurements, we find that in N2, gas molecules collide with ions diffusely--they are reemitted at random angles relative to the gas molecule incoming angle--and inelastically. Meanwhile, in He, gas molecules collide specularly and elastically and are emitted from ion surfaces at determined angles. The results can be rationalized on the basis of the momentum transferred per collision; in the case of He, individual gas molecule collisions minimally perturb the atoms within a cluster ion (internal motion), while in the case of N2, individual gas molecules have sufficiently large momentum to alter the internal motion in organic ions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An exact hard-spheres scattering model for the mobilities of polyatomic ions

We describe an exact hard-spheres scattering model for calculating the gas phase mobilities of polyatomic ions. Ion mobility measurements have recently been used to deduce structural information for clusters and biomolecules in the gas phase. In virtually all of the previous ion mobility studies, mobilities were evaluated for comparison with the experimental data using a projection approximatio...

متن کامل

Improving Ion Mobility Measurement Sensitivity by Utilizing Helium in an Ion Funnel Trap

Ion mobility instruments that utilize nitrogen as buffer gas are often preceded by an ion trap and accumulation region that also uses nitrogen, and for different inert gases, no significant effects upon performance are expected for ion mobility spectrometry (IMS) of larger ions. However, we have observed significantly improved performance for an ion funnel trap upon adding helium; the signal in...

متن کامل

The structure of gas-phase bradykinin fragment 1-5 (RPPGF) ions: an ion mobility spectrometry and H/D exchange ion-molecule reaction chemistry study.

Ion mobility-mass spectrometry (IM-MS) data is interpreted as evidence that gas-phase bradykinin fragment 1-5 (BK1-5, RPPGF) [M + H](+) ions exist as three distinct structural forms, and the relative abundances of the structural forms depend on the solvent used to prepare the matrix-assisted laser desorption ionization (MALDI) samples. Samples prepared from organic rich solvents (90% methanol/1...

متن کامل

Differential ion mobility separations in up to 100% helium using microchips.

The performance of differential IMS (FAIMS) analyzers is much enhanced by gases comprising He, especially He/N2 mixtures. However, electrical breakdown has limited the He fraction to ~50%-75%, depending on the field strength. By the Paschen law, the threshold field for breakdown increases at shorter distances. This allows FAIMS using chips with microscopic channels to utilize much stronger fiel...

متن کامل

PMM - 111 Nanoelectrospray Differential Ion Mobility Spectrometry for Protein Sizing and Molecular Mass Determination: Method Development and Validation

The characterization of large biomolecules, including the determination of their size and molecular mass (Mr), is important for understanding fundamental aspects of their biochemical behavior. Even though MS has dominated this type of analysis, another similar technique based on nanoelectrospray ion mobility spectrometry, referred to as gas phase electrophoretic mobility molecule analysis (GEMM...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Physical chemistry chemical physics : PCCP

دوره 17 22  شماره 

صفحات  -

تاریخ انتشار 2015