Illegal intra-corporeal packets: can dual energy CT be used for the evaluation of cocaine concentration? A cross sectional study
نویسندگان
چکیده
BACKGROUND The recent implementation of the dual energy technology on CT-scanners has opened new perspectives in tissue and material characterization. This study aims to evaluate whether dual energy CT can be used to assess the concentration of cocaine of intra-intestinal illegal packets. METHODS The study was approved by the institutional review board of our institution (CER 13_027_R). From November 2010 to May 2013, all consecutive conveyors in whom a low-dose abdominal CT (LDCT) revealed the presence of illegal intra-corporeal drug packets underwent a dual energy CT series (gemstone spectral imaging) targeted on one container. The mean radiological density (HU) of these packets was measured on the LDCT series, and on the monochromatic dual energy series, at 40 and 140 keV. The difference between the HU at 40 and 140 keV was reported as ∆HU. The effective atomic number Z(eff) was also measured on the monochromatic series. A chemical analysis was performed after expulsion to select cocaine containing packets, and to determine their cocaine concentrations. A correlation analysis was performed between HU, ∆HU and Z(eff), with regard to the percentage of cocaine. RESULTS Fifty-four cocaine conveyors were included. The mean cocaine content of the packets was 36.8% (range 11.2-80, SD 15.4), the mean radiologic density 105 HU, the mean Z(eff) 8.7 and the mean ∆HU 163. The cocaine content was correlated with the ∆HU (0.57, p < 0.001), with the Z(eff) (r = 0.56, p < 0.001) but not with radiologic density (r = 0.25, p = 0.064). ∆HU >200 was 0.9 (9 of 10) sensitive and 0.82 (36 of 44) specific to predict a cocaine concentration higher than 50%. CONCLUSION Measuring ∆HU or Z(eff) on dual energy monochromatic CT series can be used to detect ingested packets with cocaine concentration >50%.
منابع مشابه
A novel dual energy CT-based attenuation correction method in PET/CT systems: A phantom study
In present PET/CT scanners, PET attenuation correction is performed by relying on the information given by CT scan. In the CT-based attenuation correction methods, dual-energy technique (DECT) is the most accurate approach, which has been limited due to the increasing patient dose. In this feasibility study, we have introduced a new method that can implement dual-en...
متن کاملComparing 511 keV Attenuation Maps Obtained from Different Energy Mapping Methods for CT Based Attenuation Correction of PET Data
Introduction: The advent of dual-modality PET/CT scanners has revolutionized clinical oncology by improving lesion localization and facilitating treatment planning for radiotherapy. In addition, the use of CT images for CT-based attenuation correction (CTAC) decreases the overall scanning time and creates a noise-free attenuation map (6map). CTAC methods include scaling, s...
متن کاملEvaluation of absorption efficiency of Zeolite ZSM-5 in the removal of styrene vapors
Background: Volatile organic compounds (VOCs) are one of the most important and prevalent air pollutants. The vapor produced as a result of the vaporization ‎of these compounds, even at very low concentrations, is harmful to the environment and human health. Thus, the aim of this study was to evaluate the removal of styrene vapor from the air flow using Zeolite ‎(ZSM-5) in a continuous ...
متن کاملP-34: Evidence for The Influence of Illegal Drug Consumption on Male Fertility
Background: Exposure to certain drugs and toxins plays an important role in male infertility. Even fancy using of illegal drugs is an important factor in evaluation of male infertility. There is evidence in previous literature that this drug has harmful effects on fertility, but data based on evidence is limited. The purpose of this study was to evaluate the infertile couples in one of the infe...
متن کاملHeroin Body Packer’s Death in Shiraz, Iran; a Case Report and Literature Review
Background: Intra-corporeal concealment of illicit drugs known as ‘body packing’ is uncommonly reported. These drugs mainly comprise opium, heroin, cocaine, 3,4-methylenedioxymethamphetamine (ecstasy), amphetamines, and marijuana or hashish. Body packers may also be called swallowers, internal carriers, couriers or mules. Although this practice is not new, its medical complications have alway...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 16 شماره
صفحات -
تاریخ انتشار 2016