Intravascular magnetic resonance imaging using a loopless catheter antenna.
نویسندگان
چکیده
Recently, intravascular catheter probes have been developed to increase signal-to-noise ratio (SNR) for MR imaging of blood vessels. Miniaturization of these catheter probes without degrading their performances is very critical in imaging small vessels such as coronary arteries. Catheter coils have a loop incorporated in their structure and have limitations in physical dimensions and electromagnetic properties. The use of a loopless intravascular catheter antenna is proposed to overcome these problems. The catheter antenna is essentially a dipole, which makes a very thin diameter possible, and its electronic circuitry can be placed outside the blood vessels without performance degradation. The theoretical foundation for the design and operation of the catheter antenna is presented. Several catheter antennae, as small as 1.5 French, were constructed and tested on phantoms and rabbits with great success. The catheter antenna has a simple structure and is easy to design, implement, and operate.
منابع مشابه
Intravascular MR imaging-guided balloon angioplasty with an MR imaging guide wire: feasibility study in rabbits.
PURPOSE To develop a technique for intravascular magnetic resonance (MR)-guided balloon angioplasty with use of an MR imaging guide wire. MATERIALS AND METHODS An MR imaging guide wire (0.6-mm loopless antenna) that could be placed within a balloon catheter was manufactured. The guide wire was expected to function as either an MR receiver probe in real-time MR imaging or a guide wire for use ...
متن کاملRF transmit power limit for the barewire loopless catheter antenna.
The safety of the barewire loopless catheter antenna in transmit mode is addressed with respect to radiofrequency (RF) heating. Analytical expressions for electric field and specific absorption rate (SAR) distributions surrounding the antenna are postulated and experimentally verified. Limiting RF transmit power to 40-70 mW time-averaged power, depending on the specific antenna design, will ens...
متن کاملIn-stent lumen visualization using intravascular MRI and a bSSFP sequence
Introduction Performing magnetic resonance imaging inside metallic vascular stents still represents a major challenge in many cases. Metallic stents are known to hinder visualization of the inner lumen as a result of both susceptibility artefacts and radiofrequency shielding effects [1]. Proposed solutions to the radiofrequency shielding effects include the use of sequences with an increased fl...
متن کاملIntravascular extended sensitivity (IVES) MRI antennas.
The design and application of an intravascular extended sensitivity (IVES) MRI antenna is described. The device is a loopless antenna design that incorporates both an insulating, dielectric coating and a winding of the antenna whip into a helical shape. Because this antenna produces a broad region of high SNR and also allows for imaging near the tip of the device, it is useful for imaging long,...
متن کاملMultiple field of view MR fluoroscopy.
This work describes a real-time imaging and visualization technique that allows multiple field of view (FOV) imaging. A stream of images from a single receiver channel can be reconstructed at multiple FOVs within each image frame. Alternately, or in addition, when multiple receiver channels are available, image streams from each channel can be independently reconstructed at multiple FOVs. The i...