Difficulty Using Smart Pump Logs to Recreate a Patient Safety Event: Case Study and Considerations for Pump Enhancements

نویسندگان

  • Andrew A M Ibey
  • Derek Andrews
  • Barb Ferreira
چکیده

The authors present a case in which a physical anomaly with an infusion pump resulted in an unforeseen fault that the nurse's attempts to resolve unknowingly exacerbated. This case study presents the first report in the literature to detail the difficulty in recreating a patient safety event using smart pump logs, support server continuous quality improvement (CQI) data, and the drug order entry system to elucidate the clinical scenario. A 75-year-old male patient presented to a major teaching hospital and was admitted to the intensive care unit (ICU) with a massive gastrointestinal bleed and myocardial infarction, then stabilized. One of the patient's pumps alarmed "communication error" on the display. The display gave no explicit instructions about how to resolve the issue, and resolution was not intuitive. Attempts to clear the alarm failed, so the module was disconnected to reprogram the infusion, causing an interruption in the dopamine. Over the course of approximately 2 min of troubleshooting, the patient's blood pressure decreased from 109/50 to 60/30, with a rapid pulse change from a consistent 95 up to 115 and subsequently 135 beats per minute. A cardiac arrest ensued and a code blue was called. All cardiac drugs, including the dopamine, were suspended during the code. Cardiopulmonary resuscitation was performed and the patient survived the code. Post-code, the dopamine and epinephrine were restarted, and the norepinephrine was discontinued. The patient's condition remained very unstable. Pump logs and the server database were queried to locate relevant equipment. It was concluded that dirty contacts on the inter-unit interface (IUI) connectors between the PC unit (PCU) and the modules caused the alarm message "communication error" to appear on the PCU display. Learning yielded a nursing practice alert to clarify how a nurse should resolve a "communication error", and appropriate cleaning protocols were promptly implemented. The investigation found smart pump event logs and proprietary software are not designed with any forethought as to retrospective reconstruction of incident investigations, leaving facilities to cobble together pieces of information from multiple sources to determine what occurred. The authors also suggest further pump enhancements, challenging pump manufacturers to go to the next level of integration and enable greater patient safety with smart infusion pumps.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A case study on the safety impact of implementing smart patient-controlled analgesic pumps at a tertiary care academic medical center.

BACKGROUND As with the use of any therapy involving opioids, patient-controlled analgesia (PCA)-related errors can lead to overdose and even death. "Smart" (computerized) pumps have medication safety enhancements, particularly those related to operator errors during administration, to improve overall safety and efficacy. After the occurrence of PCA-related errors that occurred at a tertiary car...

متن کامل

The impact of traditional and smart pump infusion technology on nurse medication administration performance in a simulated inpatient unit

OBJECTIVE Assess the impact of infusion pump technologies (traditional pump vs smart pump vs smart pump with barcode) on nurses' ability to safely administer intravenous medications. DESIGN Experimental study with a repeated measures design. SETTING High-fidelity simulated inpatient unit. RESULTS The nurses remedied 60% of "wrong drug" errors. This rate did not vary as a function of pump ...

متن کامل

Application of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)

Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...

متن کامل

Off-Pump Versus On-Pump Coronary Artery Bypass Graft Surgery, prospective cohort study

Introduction: Coronary artery bypass grafting is a surgical operation that bypasses atherosclerotic coronary vessels and restores blood flow to the ischemic zone of hearts. And two different conventional methods are ON-pump CABG, and Off-pump CABG.  Altogether, the efficacy and safety of these two types of surgical procedures are still under debate. In this study, we aim to com...

متن کامل

Assessment of energy efficiency in pump stations of pressurized irrigation systems (case study: Qazvin and Kermanshah provinces)

About 20% of the electricity produced in the world is consumed in rotary equipment for conveying fluids such as water, gas, air, and other liquids, while the loss of energy consumption in this sector is more than 60%. The aim of this study is to evaluate different efficiencies in the pumping stations in the pressurized irrigation systems to address low energy efficiency issues in the pump stati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2016