Comparison of image quality and radiation dose in computed tomography angiography of the peripheral arteries using tube voltage of 80 kV versus 100 kV.
نویسندگان
چکیده
OBJECTIVE To compare the image quality and dose of radiation in two groups of patients undergoing CT angiography of the lower limbs, one with tube voltage of 80 kV and the other with tube voltage of 100 kV. MATERIAL AND METHODS We performed CT angiography of the lower limbs in 60 patients with suspected peripheral arterial disease. Patients were randomly assigned to one of two groups; in one group, CT angiography was performed using a tube voltage of 80kV, whereas in the other it was performed using 100 kV. The remaining acquisition parameters were the same in both groups. The images were analyzed by quantifying vascular density (VD) and noise (N) and by calculating the quotients density/noise (QVDN) and contrast/noise (QCN). Two radiologists working independently evaluated the subjective quality of the images. We calculated the estimated effective dose (EED) based on the dose-length product (DLP). RESULTS In the group studied at 80 kV, VD was significantly higher (462.5 UH ± 95.6 vs. 372 UH ± 100.9; P<.001), QVDN was significantly higher (241.9 ± 48.1 vs. 194.3 ± 49.6; P<.001), and there were trends toward higher N (21.3 UH ± 13 vs. 16.3 UH ± 3.5; P=.098) and toward higher QCN (21.4 ± 12.1 vs. 22.9 ± 9.1; P=.15). No significant differences were found in the subjective quality of the images. The EED was significantly lower in the group studied at 80 kV (4.73 mSv ± 1.1 vs. 9.6 mSv ± 2.2; P<.001). CONCLUSION Using 80 kV instead of 100 kV for CT angiography of the lower limbs reduces the dose of radiation without affecting the diagnostic efficacy of the study.
منابع مشابه
Comparison of Image Quality of Low Voltage 64-slice Multidetector CT Angiography with the Standard Condition in Patients Suspected of Pulmonary Embolism
Introduction: Reduction of peak kilovoltage (kV) setting has been a useful approach to d creating radiation dose; however, it may have varied effects on noise and the accuracy of diagnosis. Thus, we compared image quality between low (80 kV) and standard kilovoltage (100 kV) protocols. Material and Methods: This triple blind non-randomized parallel quasi-experimental study was conducted on 140 ...
متن کامل[Dual energy CT angiography of the carotid arteries: quality, bone subtraction, and radiation dosage using tube voltage 80/140 kV versus 100/140 kV].
OBJECTIVE To study the differences in vascular image quality, bone subtraction, and dose of radiation of dual energy CT angiography of the supraaortic trunks using different tube voltages. MATERIAL AND METHODS We reviewed the CT angiograms of the supraaortic trunks in 46 patients acquired with a 128-slice dual source CT scanner using two voltage protocols (80/140 kV and 100/140 kV). The "head...
متن کاملLow kilovolt “prospective ECG-triggering” vs. “retrospective ECG-gating” coronary CTA: comparison of image quality and radiation dose
Background: To compare image quality and radiation doses of low kilovolt (kV) “prospective ECG-triggering” (PT) and standard “retrospective ECG-gating” (RG) coronary computed tomography (CT) angiography. Materials and Methods: A total of 101 consecutive patients (76 males, 25 females; mean age: 55.44 ± 8.28 years) with low-to-intermediate risk status for coronary artery disease and with a body ...
متن کاملDiagnostic quality of CT pulmonary angiography in pulmonary thromboembolism: A comparison of three different kV values
BACKGROUND Our purpose was to evaluate the effectiveness of different kilovolt (kV) uses in computed tomography pulmonary angiography (CTPA) in the diagnosis of pulmonary thromboembolism (PTE). We also aimed to establish the optimal kV value and investigate the possibility of obtaining appropriate imaging quality with minimal radiation dose. MATERIAL AND METHODS We compared 120, 100, and 80 k...
متن کاملEffect of tube voltage on image quality in 64-section multidetector 3D CT angiography: Evaluation with a vascular phantom with superimposed bone skull structures.
BACKGROUND AND PURPOSE Optimal tube voltage and tube current settings are not well established. The purpose of our study was to investigate the image quality on 3D CT angiograms of the brain at various kilovoltage settings by evaluating the depiction of simulated intracranial lesions by using a vascular phantom. MATERIALS AND METHODS An anthropomorphic vascular phantom with superimposed bone ...