Radiation Levels from Toilets Used By Patients Injected with 99mTc-based Radiopharmaceuticals in Ibadan

نویسندگان

  • John Enyi Ejeh
  • Tolulope Hadrat Abiodun
  • Kayode Solomon Adedapo
  • Yetunde Ajoke Onimode
  • Olusegun Akinwale Ayeni
چکیده

OBJECTIVE The use of radionuclides in patients undergoing nuclear medicine procedures presents a special concern on the safety of not only the patients but also of those who come in contact with such patients either at the nuclear medicine centre or at home after discharge from the facility. This has heightened the public concern about nuclear medicine especially in Nigeria where the practice is new. When patients are injected with radioactivity for nuclear medicine procedures they excrete most of the radioactivity via urine even before leaving the nuclear medicine facility. Therefore, we set out to survey the toilets used by these patients in the hospital for radiation levels to know the radiation risk posed by the 'radioactive urine' of the patients to the general public and radiation workers respectively. METHODS A portable digital radiation survey meter was used for measurement of radioactivity in toilets used by a total number of 202 patients injected with 99mTc-based radiopharmaceuticals over a period of 60 days for the level of radioactivity. RESULTS The minimum background radiation level measured was 0.18 µSv/h while the maximum was 0.44 µSv/h and the mean background reading was 0.28 µSv/h. The readings recorded for the male toilets were: 0.1 µSv/h minimum, 5.62 µSv/h maximum with a mean of 0.52 µSv/h while those for the female patients were 0.19 µSv/h minimum, 21.73 µSv/h maximum and a mean of 3.3 µSv/h. CONCLUSIONS In conclusion, the radiation levels from toilets used by patients injected with 99mTc-based radiopharmaceuticals were within reasonable and acceptable limits and do not pose significant radiation risk to others.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

External radiation dose from patients received diagnostic doses of ²º¹Tl-Chloride and 99mTc-MIBI [Persian]

Patients receiving diagnostic doses of radiopharmaceuticals become a source of contamination and exposure for those who come in contact with them, such as nuclear medicine technologists, relatives and nurses. Therefore, the measurement of external radiation dose from these patients is necessary. In this study, the dose rates at distances of 10, 50 and 100cm from 70 patients who received d...

متن کامل

Radiation dose to the nuclear medicine nurses

Background: People who have been administrated radiopharmaceuticals could be a source of radiation to their relatives, medical nurses, and people who are in contact with them. The aim of this work was to estimate radiation dose received by nuclear medicine nurses. Materials and Methods: In this study, the dose rates at various distances of 5 – 100 cm from 70 patients, who were administered diag...

متن کامل

Determination of Uterus Absorbed Dose by Patients following Myocardial Perfusion Scan using TLD and Conjugate View Methods

Introduction: The determination of patient’s absorbed dose is the first step of radiation protection which depends on the quantification of organ activity in nuclear medicine. The aim of the present study was to determine the absorbed dose by patient’s uterus following myocardial perfusion scan with 99mTC-sestamibi using Theroluminescnce dosimetry (TLD) and conjugate-view metho...

متن کامل

اندازه‌گیری دوز جذبی کلیه‌ها، کبد، مثانه و تخمدان در آزمایش سنتی گرافی کلیه با رادیو داروهای 99mTc-EC و 99mTc-DTPA با استفاده از فنتوم به روش دوزیمتری ترمولومینسانس

    Background: In this survey the absorbed dose by kidneys, bladder, liver and ovaries with 99mTc-EC (99mTc Ethylene dicysteine) renal scintigraphy was measured and compared with the absorbed dose from 99mTc-DTPA (99mTc - Dietheylne Triamine Penta-Acid), which often is used in renal scintigraphy.Methods: In this applicable study, we used a water phantom with geometrical sizes similar to that o...

متن کامل

Evaluating the Effect of Injected Dose of 99mTc- MIBI on the Quantitative Parameters of Myocardial Perfusion Imaging

Background: 99mTc-MIBI cardiac perfusion scanning is recognized as a clinically useful method in evaluating coronary artery disease. By the implementation of new imaging techniques and systems, it seems possible to obtain high-quality images with a lower dose of radiopharmaceuticals. The purpose of this study was to evaluate the effect of injection dose of 99mTc-MIBI on quantitative parameters ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 23  شماره 

صفحات  -

تاریخ انتشار 2014