SWI-based method for emphasizing susceptivity changes on liver T2* multi-echo gradient-echo MRI
نویسندگان
چکیده
Introduction It is well known that the susceptibility difference between tissues, such as venous blood and surrounding tissue, causes a different bulk magnetization that can be observed both in magnitude and phase images: as a signal amplitude loss due to a reduced T2*, and as a local frequency variation of the protons inside the vessel that results in a phase angle Φ of the venous blood signal, respectively. So, these two types of information can be combined for obtaining an image with susceptibility related contrast (susceptibility weighted imaging SWI) [1]. In the clinical MRI practice, it is common to assess liver iron overload by T2* multi-echo gradient-echo images. The currently used methods involve manual drawing of a region of interest (ROI) within liver parenchyma carefully excluding vessels; then, evaluation of a representative liver T2* value is done by fitting an appropriate model to the signal decay within the ROIs vs. the echo time. Such ROI-based methods may suffer from sampling errors due to user-dependent placement of the ROI and erroneous inclusion in the ROI of regions close to liver vessels. Arterial vessel in T2*-weighted images appear as bright pixels with a quite good contrast with the parenchyma, but venous vessels often are not visible in T2*weighted images, so an erroneous inclusion of venous vessels in the ROI can occur. In the present work we suggest a method, based on a SWI approach, that increases the contrast between tissues of different susceptivity, in liver T2* multi-echo gradient-echo images. Materials and methods Liver MRI were acquired by using a 1.5-T MR scanner (GE Excite, Milwaukee, WI, USA) with an eight-element cardiac phased array coil. Fast gradient-echo multi-echo sequence (flip angle 25°, matrix 192×256 pixels, field of view 40×40 cm, bandwidth 62.5 kHz, slice thickness 8.0 mm, number of excitations 1, repetition time 25 ms) was used and both amplitude and phase images were memorized. A single transverse slice through the liver was obtained at 10 different TEs (2.0–21.8 ms, increasing in 2.2-ms increments) in a single end-expiratory breath-hold; the total acquisition time was about 5 s [2]. Magnitude and phase images stored during acquisition, for each TE, were processed offline using Matlab (The Mathworks, Natick, MA, USA). Postprocessing operation included the following steps [1, 3]: 1. high-pass filtering of the phase image, for background fields inhomogeneities removal; the filter was performed with a 2D circular lowpass Hamming window with kernel k and then transformed in high-pass filter by a complex division; 2. phase mask definition, in order to suppress the signal of the pixels having specific phase values, due to the presence of high local susceptibility; 3. product of the amplitude image and m-times the mask, in order to obtain a SWI-like image from T2* multi-echo gradient-echo images. Results In figure 1a, amplitude image with two selected ROIs is shown; it includes also a zoom of a region including the ROIs. The relevant mean-intensity vs.TE curves are shown in fig 1b; figures show that selecting two ROIs in regions apparently similar, the mean intensity-TE curves are different. It is due to the presence of a different susceptivity variation in the ROI1, as it appears in figure 1e. Figure 1c shows the phase image, while figure 1d is relevant to the resulting mask, obtained with filter kernel k=64 and multiplying factor m=7, to be applied on the amplitude image; in figure 1e the final SWI-like image is shown, where the dark regions, with higher susceptivity variations, are emphasized (see also the zoomed region).
منابع مشابه
Background Gradient Correction for Water and Fat Quantification in 2D Liver Imaging
Introduction Fatty infiltration of the liver is one of the primary features of nonalcoholic fatty liver disease. Therefore, accurate quantification of the liver fat content is an important factor in detecting hepatic diseases. MRI is an efficient noninvasive tool for assessing liver fat content. A commonly used liver fat quantification technique with MRI is a dual echo imaging (two gradient seq...
متن کاملNon-invasive quantification of liver fat content by different Gradient Echo MRI sequences in patients with Non-Alcoholic Fatty Liver Disease (NAFLD)
Introduction: Non-invasive quantification of liver fat by Gradient echo (GRE) Technique is an interesting issue in quantitative MRI. Despite the numerous advantages of this technique, fat measurement maybe biased by confounding and effects. The aim of this study was to evaluate the GRE pulse sequences with different and weighting for liver fat quantification in patients with...
متن کاملWEEKDAY EDUCATIONAL COURSE Everything You Wanted to Know about Magnetic Susceptibility & Why It Is Important
Gradient Recalled Echo (GRE) based MR imaging techniques have wide applications in MRI. Due to the absence of refocusing RF pulses GRE sequences are fast and since low flip angles are usually applied, GRE sequences have low specific absorption rate, hence are particularly well suited for high field MRI. While MR signal generated from GRE techniques is complex, most traditional applications rely...
متن کاملاندازه گیری غیریکنواختی امواج رادیوئی در ام آر آی
Introduction: Non-uniformity is one of the most important parameters affecting MRI images which can lead to harmful effects in the diagnosis and analysis of qualitative and quantitative methods. The present study introduced a method for measuring RF non-homogeneity in MRI systems. Methods and Materials: To verify the uniformity of B0 and B1 fields, a cylindrical phantom with a diameter of 24 c...
متن کاملSusceptibility-weighted MR imaging: a better technique in the detection of capillary telangiectasia compared with T2* gradient-echo.
BACKGROUND AND PURPOSE Enhancing lesions on brain MR imaging can present a diagnostic quandary as both benign lesions such as brain capillary telangiectasia and pathologic lesions such as demyelination may appear similar. Stagnation of blood in low-flow venous channels of brain capillary telangiectasias results in susceptibility effect secondary to the increased local deoxyhemoglobin. Both T2* ...