Refixation of osteochondral fractures by ultrasound-activated, resorbable pins

نویسندگان

  • H. Neumann
  • A. P. Schulz
  • J. Gille
  • M. Klinger
  • C. Jürgens
  • N. Reimers
  • B. Kienast
چکیده

OBJECTIVES Osteochondral injuries, if not treated adequately, often lead to severe osteoarthritis. Possible treatment options include refixation of the fragment or replacement therapies such as Pridie drilling, microfracture or osteochondral grafts, all of which have certain disadvantages. Only refixation of the fragment can produce a smooth and resilient joint surface. The aim of this study was the evaluation of an ultrasound-activated bioresorbable pin for the refixation of osteochondral fragments under physiological conditions. METHODS In 16 Merino sheep, specific osteochondral fragments of the medial femoral condyle were produced and refixed with one of conventional bioresorbable pins, titanium screws or ultrasound-activated pins. Macro- and microscopic scoring was undertaken after three months. RESULTS The healing ratio with ultrasound-activated pins was higher than with conventional pins. No negative heat effect on cartilage has been shown. CONCLUSION As the material is bioresorbable, no further surgery is required to remove the implant. MRI imaging is not compromised, as it is with implanted screws. The use of bioresorbable pins using ultrasound is a promising technology for the refixation of osteochondral fractures.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Refixation of Osteochondral Fractures by an Ultrasound-Activated Pin System – An Ovine In Vivo Examination Using CT and Scanning Electron Microscope

BACKGROUND Osteochondral injuries, if not treated appropriately, often lead to severe osteoarthritis of the affected joint. Without refixation of the osteochondral fragment, human cartilage only repairs these defects imperfectly. All existing refixation systems for chondral defects have disadvantages, for instance bad MRI quality in the postoperative follow-up or low anchoring forces. To addres...

متن کامل

Long-Term Clinical and MRI Results after Refixation of osteochondral Fractures with resorbable Implants

AIM Refixation of osteochondral fractures with resorbable implants is a common surgical treatment. There are almost no studies that prove good clinical outcomes. Hence, the aim of the study was to evaluate the mid-term results after refixation of osteochondral fractures. METHODS The results of 12 patients were recorded 6.5 (±1) years after refixation of osteochondral fractures measuring 3.4 c...

متن کامل

Bioabsorbable Pins for Treatment of Osteochondral Fractures of the Knee after Acute Patella Dislocation in Children and Young Adolescents

A retrospective study was performed on the use of bioabsorbable pins in the fixation of osteochondral fractures (OCFs) after traumatic patellar dislocation in children. Eighteen children (13 females, 5 males) aged 11 to 15 years (mean age 13.1 years) with osteochondral fracture (OCF) of the knee joint were treated at the authors' institution. Followup ranged from 22 months to 5 years. Diagnosis...

متن کامل

Use of ultrasound-activated resorbable poly-D-L-lactide pins (SonicPins) and foil panels (Resorb-X) for horizontal bone augmentation of the maxillary and mandibular alveolar ridges.

Horizontal bone augmentation of the maxillary and mandibular alveolar ridges has been conventionally performed using mini titanium alloy screws. The titanium alloy screws are used to fixate corticocancellous block grafts to the recipient site or for tenting the mucoperiosteum to retain particulate bone grafts. Nonresorbable guided tissue regenerative membranes reinforced with titanium have also...

متن کامل

Fixation of osteochondral fractures in rabbit knees. A comparison of Kirschner wires, fibrin sealant, and polydioxanone pins.

We compared fibrin sealant, polydioxanone (PDS) pins and Kirschner wires in the fixation of osteochondral fractures in rabbit knees. Standardised osteochondral fractures of the right medial femoral condyle were made in 56 adult New Zealand white rabbits. There were equal groups of control knees, and those which had Kirschner-wire, fibrin-sealant or PDS-pin fixation. No external immobilisation w...

متن کامل