Experimental Investigation on the Performance of Ground-source Heat Pump with the Refrigerant R410A

نویسندگان

  • Junhao Niu
  • Huagen Wu
  • Yunda Dong
  • Junhao NIU
  • Huagen WU
  • Yunda DONG
چکیده

Nowadays, in some small and medium-sized heat pumps, refrigerant R410A has been used widely because of the good thermodynamic performance and environmental protection. Firstly the principles of the system and the characteristics of refrigerant has been demonstrates. The paper has set up a heat pump system with the refrigerant R410A and the performance parameters under different working conditions were tested and analyzed. The results showed that when the condensation temperature increased from 30°C to 60°C, the cooling capacity decreased by 33%, the input power increased by 97.8%, and COP decreased by 66%. As the evaporation temperature increased from 0°C to 12.5°C, the refrigerating capacity increased by 55% and the input power increased by 20%. Drop in chilled water and cooling water flow rate are both harmful to the refrigeration capacity. Chilled water flow rate must be controlled higher than 35% of the rated flow rate. The inlet temperature of cooling water drops can improve the cooling capacity. When the cooling water inlet temperature increased from 18°C to 30°C, the unit COP decreased by 40.8%. Chilled water inlet temperature rise can improve the evaporation pressure of the system, and hereby improve the cooling capacity and COP. When the chilled water inlet temperature increased from 10°C to 25°C, COP improved by 63%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of Vapor Injection Heat Pump System with a Flash

Title of Dissertation: INVESTIGATION OF VAPOR INJECTION HEAT PUMP SYSTEM WITH A FLASH TANK UTILIZING R410A AND LOW-GWP REFRIGERANT R32 Xing Xu, Doctor of Philosophy, 2012 Dissertation Directed by: Professor Reinhard Radermacher Department of Mechanical Engineering Vapor injection technique has proven to be effective in improving heat pump system performance, especially for cooling application a...

متن کامل

01 The conceptual design of the photovoltaic solar thermal collector hybrid system and the ground source heat pump to provide electricity, heating and cooling a residential building focusing on technical, economic and environmental parameters.

This paper attempts to present and compare four solar assisted ground source heat pump combined systems with series and parallel layouts and direct and indirect heat exchange in Zahedan in order to supply part of the electricity demand for equipment and selling surplus electricity to the grid as a source of project financing and revenue generation for residents, moreover, fulfill the region's n...

متن کامل

Performance Investigation of Refrigerant Vapor-Injection Technique for Residential Heat Pump Systems

An 11 kW R410A heat pump system with a two-stage vapor-injected scroll compressor has been developed and tested. A conventional heat pump system with a scroll compressor having the same displacement volume to the vapor-injected scroll compressor has been tested under the same conditions to serve as a baseline. The vaporinjected scroll compressor has been tested with the cycle options of both fl...

متن کامل

Performance analysis of a novel dual-nozzle ejector enhanced cycle for solar assisted air-source heat pump systems

In this study, a novel dual-nozzle ejector enhanced vapor-compression cycle (DEVC) for solar assisted airsource heat pump systems is proposed. In DEVC, the use of the dual-nozzle ejector for recovering the expansion losses is a very promising approach to improve the cycle performance. A mathematical model of the DEVC is developed to predict its performance under specified operating conditions. ...

متن کامل

Evaluation of Lubricants for R410A/R407C Applications in Scroll Compressor

Sonny G. Sundaresan Copeland Corporation Sidney, Ohio, U.S.A. HCFC 22 currently used in Air-Conditioning and Heat Pump applications, is being replaced by R407C and R410A, both HFC 32 based blends. Scroll compressors are being developed to meet the improved efficiency and other system performance requirements in Air-Conditioning and Heat Pump products in North America, Europe and Asia-Pacific. L...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017