Porcine model to compare real-time intraocular pressure during LASIK with a mechanical microkeratome and femtosecond laser.

نویسندگان

  • José L Hernández-Verdejo
  • Miguel A Teus
  • José M Román
  • Gema Bolívar
چکیده

PURPOSE To compare real-time intraocular pressure (IOP) during laser in situ keratomileusis (LASIK) in porcine eyes using two types of microkeratomes. METHODS An interventional, prospective study of two microkeratomes: a Moria 2 (Moria group) and an IntraLase femtosecond laser (IntraLase Corp., Irvine, CA; IntraLase group). These devices were used to create lamellar corneal flaps in freshly enucleated porcine eyes. The IOP changes induced by the procedures were recorded with a reusable blood pressure transducer connected to the anterior chamber by direct cannulation. RESULTS Seven porcine eyes were studied in each group. The IOP increased during the suctioning phase, reaching a mean of 122.52 +/- 30.40 and 160.52 +/- 22.73 mm Hg during the cutting phase in the Moria group (the total time in this group was 36.42 +/- 7.48 seconds; suctioning required 21.42 +/- 7.48 seconds and the cutting phase, 15 +/- 2.88 seconds). In the IntraLase group, the IOP reached 89.24 +/- 24.26 mm Hg during the suctioning phase and 119.33 +/- 15.88 mm Hg during the intrastromal laser application (the total time was 92.85 +/- 13.49 seconds; suctioning required 40.00 +/- 9.57 seconds and the cutting phase 52.85 +/- 5.66 seconds). Both IOPs during both phases differed significantly between the two groups (P = 0.01 for all comparisons). CONCLUSIONS Real-time IOP can be measured during LASIK using a transducer connected to the anterior chamber. The results showed a significant increase in IOP during the procedure in both groups, although with the IntraLase the IOP seemed to increase to a lesser extent than with the conventional mechanical microkeratome.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Factors Influencing Intraocular Pressure Changes after Laser In Situ Keratomileusis with Flaps Created by Femtosecond Laser or Mechanical Microkeratome

The aim of this study is to describe factors that influence the measured intraocular pressure (IOP) change and to develop a predictive model after myopic laser in situ keratomileusis (LASIK) with a femtosecond (FS) laser or a microkeratome (MK). We retrospectively reviewed preoperative, intraoperative, and 12-month postoperative medical records in 2485 eyes of 1309 patients who underwent LASIK ...

متن کامل

Incidence of Posterior Vitreous Detachment After Femtosecond LASIK Compared With Microkeratome LASIK.

PURPOSE To compare the incidence of posterior vitreous detachment (PVD) after femtosecond and microkeratome laser in situ keratomileusis (LASIK). SETTING Rowad Correction Centre, Cairo, Egypt (a private center affiliated to Cairo University). DESIGN Prospective, nonrandomized comparative unmasked study. METHODS The study was conducted at a single laser center. Eligible patients chose betw...

متن کامل

Femtosecond laser versus mechanical microkeratome: a retrospective comparison of visual outcomes at 3 months.

PURPOSE To compare the visual outcomes of LASIK procedures in which flaps were created with a femtosecond laser (IntraLase FS 60Hz, Abbott Medical Optics [AMO]) to procedures in which flaps were created with a mechanical microkeratome (Moria Evo3 One Use-Plus, Moria SA). METHODS A retrospective analysis was performed on 2000 eyes treated in 2008 for low myopia and astigmatism (sphere < -3.00 ...

متن کامل

In vivo corneal confocal microscopy comparison of intralase femtosecond laser and mechanical microkeratome for laser in situ keratomileusis.

PURPOSE To assess and compare corneal modifications induced by IntraLase PulsionFS femtosecond laser and mechanical microkeratome Hansatome for laser in situ keratomileusis (LASIK) using the new-generation Heidelberg Retina Tomograph II (HRT II)/Rostock Cornea Module confocal microscope. METHODS In this case-control study, 24 eyes of 12 patients were examined with the HRT II in the follow-up ...

متن کامل

Changes in retinal nerve fiber layer thickness following mechanical microkeratome-assisted versus femtosecond laser-assisted LASIK

PURPOSE To study the influence of the transient elevation of intraocular pressure during suction in laser-assisted in situ keratomileusis (LASIK) on the retinal nerve fiber layer (RNFL) thickness both in microkeratome assisted and femotsecond (FS) LASIK. PATIENTS AND METHODS An interventional case series that included 40 eyes suffering from myopia who were candidates for LASIK. All underwent ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 48 1  شماره 

صفحات  -

تاریخ انتشار 2007